File Name: DPU222RGF20WTST.pdf?i=1B332687-629E-4AF2-BE90-A4BFC8B350DE
File Size: 332.19 KB
File Type: Application/pdf
Last Modified: 5 years
Status: Available
Last checked: 9 days ago!
This Document Has Been Certified by a Professional
100% customizable
Language: English
We recommend downloading this file onto your computer
Air Conditioning Disconnects 6.1 Air Conditioning DisconnectsAir Conditioning Disconnects Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2 6 Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2 6 Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-3 Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-3 6 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V1-T6-4 V1-T6-6 6 Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 6 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 6 Learn 6 Online 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-1 Revision notesVolume 1—Residential and Light Commercial, CA08100002ETab 6—Air Conditioning DisconnectsRevision date Section Change page(s) Description12/20/2016 6.1 V1-T6-5–V1-T6-7 Content edits
Proof 1 — December 20, 2016 9:06 AM 6.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Contents6 Air Conditioning Disconnects Description Page6 Features, Benefits and Functions . . . . . . . . . . . . . V1-T6-3 Standards and Certifications . . . . . . . . . . . . . . . . . V1-T6-36 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-4 Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-66 Technical Data and Specifications . . . . . . . . . . . . . V1-T6-7 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76666 Complete Line of Fused, Unfused and Molded Case Switch Type Air Conditioning Disconnects666 Product Description Application Description6 An air conditioning disconnect (ACD) is a Fused and Non-Fused Pullouts The most widely used application for ACDs is for disconnect located between residential and light6 a loadcenter (distribution ● ON/OFF control provided by a pullout handle commercial air conditioning panel) and air conditioner. units. An ACD is installed6 Eaton’s ACD product line ● Pullout handle can be conveniently stored in the outdoors, in visible proximity provides an installer or repair to the air conditioner6 personnel with a visible disconnecting means when compartment in the OFF position, helping to prevent condensing unit. ACDs are also found in use with heat the handle from being6 performing maintenance
ACDs are also known as misplaced pumps, swimming pools, spas, whirlpools and pump disconnects, pullouts or air ● Protective shield cannot be houses, and meet 20086 conditioning switches. removed until the pullout NEC Article 422.31 (B) handle is removed, requirements for servicing6 Non-fused pullout and molded case switch devices disconnecting the power electric water heaters
Metallic enclosures are provide personnel with a Molded Case Switch6 visible ON-OFF disconnecting ● Rugged molded case galvanized steel and are installed in various locations
means. While fused pullout construction in a6 units also perform this disconnect switch that Non-metallic enclosures are a plastic (polycarbonate) function, they also provide an looks like a circuit breaker enclosure commonly used in6 additional level of protection for the air conditioner
but operates like an coastal or salt-water areas
ordinary household6 Fused and non-fused devices ● light switch Plug-in molded case switch are of a pullout design, where6 the user physically removes or “pulls out” a tab to break (included) eliminates the need for pullout handles6 the electrical connection. No need for replacement ● A molded case switch is pullout handles due to loss similar to a light switch where or theft6 the user “switches” the unit to the indicated6 ON-OFF position
6666 V1-T6-2 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 6.1Features, Benefits and Functions Standards and● Single-phase, two-wire, ● Horsepower rated (10 hp Certifications 6 240 Vac and three-phase, three-wire, 240 Vac ● maximum at 240 Vac) Padlockable door provision ● UL listed File No. E132354, E143893, E196365 6 6● NEMA 3R outdoor for safety and reduction of enclosures offered in tampering metallic and Metallic enclosures are 6 ● non-metallic versions bottom entry and exit only● Easy-to-remove high- ● Non-metallic enclosures Contact Eaton for details strength protective have knockouts and a hub and part numbers for CSA 6 shield for easier wiring provision for top access approved units
and mounting ● Non-metallic enclosures 6● Easy-to-remove front cover have a single unit door and (no screws or fasteners to remove) protective shield for 6 installer convenience● 1-inch knockouts on the bottom, back and side ● Non-metallic enclosures are durable and provide 6 6 of unit excellent resistance to● Copper-rated line and load climate changes lugs that are easily Factory-installed tamper- 6 ● accessible resistant/weather-resistant● Ample wiring space for receptacles are available as mounting with a stud gun an option on some products 6 (single keyhole, two- or three-point mounting) 6● Fused devices are service entrance rated 6Note: Fused non-metallic unitsrequire the addition of GB4NM 6ground bar to obtain a ServiceEntrance rating
6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-3 6.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Product Selection66 DPU222R Non-Fused Pullouts6 Main Ampere Maximum hp Rating Wire Size Range Cu/Al Catalog Rating 120 V 240 V 60 °C or 75 °C Number6 Galvanized Steel6 60 — Non-Metallic/Polycarbonate Enclosure 10 #14–3 DPU222R 16 60 — 10 #14–2 ACD222URNM-A2 16 DPF222R Fused Pullouts6 Main Ampere Maximum hp Rating Wire Size Range Cu/Al Catalog6 Rating 120 V 240 V 60 °C or 75 °C Number Galvanized Steel6 30 2 2 3 #14–3 DPF221R 1 60 2 3 10 #14–3 DPF222R 16 Non-Metallic 30 2 3 #14–2 ACD221RNM-A2 16 60 3 10 #14–2 ACD222RNM-A2 16 For Service Entrance applications, see footnotes below
6 Molded Case Switch DPB222R6 Main Ampere Maximum hp Rating Wire Size Range Cu/Al Catalog Rating 120 V 240 V 60 °C or 75 °C Number6 Galvanized Steel6 60 — 10 #14–3 DPB222R 3 Non-Metallic/Polycarbonate Enclosure6 60 — 10 #14–2 B60NARNM-A2 36 Notes 1 For replacement pullout head, order part number 96-3258-4
2 To obtain a Service Entrance Rating, the addition of a DPFG (ground bar kit) is required
6 3 For replacement molded case switch, order part number BR260NA
6666666666 V1-T6-4 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 6.1 ACD with 20 Ampere Ground Fault Receptacle 1DPU222RGF20 Main Maximum hp Rating Wire Size 6 Ampere Range Cu/Al Catalog Rating 120 V 240 V 60 °C or 75 °C Number 6 Non-Fused Pullouts 60 — 10 #14–3 DPU222RGF20WTST 2 6 60 Fused Pullouts — 10 #14–3 DPU222RGF20ST 6 30 2 3 #14–3 DPF221RGF20WTST 2 6 30 2 3 #14–3 DPF221RGF20ST 60 3 10 #14–3 DPF222RGF20WTST 2 6 60 3 10 #14–3 DPF222RGF20ST 6DPU222RGF15 ACD with 15 Ampere Ground Fault Receptacle 13 6 Main Ampere Maximum hp Rating Wire Size Range Cu/Al Catalog 6 Rating 120 V 240 V 60 °C or 75 °C Number Non-Fused Pullouts 6 6 60 — 10 #14–3 DPU222RGF15ST 60 — 10 #14–3 DPU222RGF15WTST 2 Fused Pullouts 6 30 2 3 #14–3 DPF221RGF15ST 30 2 3 #14–3 DPF221RGF15WTST 2 6 60 3 10 #14–3 DPF222RGF15ST 60 3 10 #14–3 DPF222RGF15WTST 2 6 Notes 1 Factory-installed GFCI receptacle
6 6 2 Includes weather-resistant/tamper-resistant receptacles to meet 2008 NEC Article 406.8 (A) and 406.11 requirements
3 NEC permits the maximum receptacle rating of a 15 A circuit to be 15 A
6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-5 6.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Three-Phase Non-Fused ACD6 DPU362A Main Maximum hp Rating Ampere Wire Size Catalog6 Rating 240 V 480 V Range Cu 75 °C Number 60 15 30 #14–4 DPU362RA666 Cross-Reference66 Cross-Reference6 Catalog Number Siemens® Description Eaton Square D® GE® (Murray®) Milbank Midwest6 Metallic/Galvanized Steel Enclosure6 30 A fused DPF221R — TF30R WF2030 U3830 U035F2 60 A fused DPF222R — TF60R WF2060 U3860 U065F16 60 A non-fused DPU222R — TFN60R — U3800 U065P0106 60 A non-fused compact design DPU222R — — WNFC2060 — — 60 A molded case switch DPB222R QO200TR TNA60R1 WNAS2060 — U065NA16 60 A non-fused with ground fault receptacle DPU222RGF20ST — TFN60RGFR WN2060GFCI U3822-20GR U065P010 30 A fused with ground fault receptacle DPF221RGF20ST — — WF2030GFCI — U035F0106 60 A fused with ground fault receptacle DPF222RGF20ST — — WF2060GFCI — U065F010 DPU222R12W 16 60 A non-fused with 1/2-inch wire harness — — — — — 60 A non-fused with 3/4-inch wire harness DPU222R34W 1 — — — — —6 60 A three-phase 600 V molded case switch DPU362RA — — — — U0653F Non-Metallic/Polycarbonate Enclosure6 30 A fused ACD221RNM-A2 — TPF30R WF2030PL — P035F 60 A fused ACD222RNM-A2 — TPF60R WF2060PL — P065F6 60 A non-fused ACD222URNM-A2 — TPN60R1 WN2060PL — P065P16 60 A molded case switch B60NARNM-A2 QO200TRNM TPNA60R1 WNAS2060PL — P065NA1 30 A fused with 15 A ground fault receptacle DPF221RGF15WRTRST — — — — —6 30 A fused with 20 A ground fault receptacle DPF221RGF20WRTRST — — — — — 60 A fused with 15 A ground fault receptacle DPF222RGF15WRTRST — — — — —6 60 A fused with 20 A ground fault receptacle DPF222RGF20WRTRST — — — — —6 60 A non-fused with 15 A ground fault receptacle DPU222RGF15WRTRST — — — — — 60 A non-fused with 20 A ground fault receptacle DPU222RGF20WRTRST — — — U3822-20GWR —6 Note 1 Eaton Quick ProSM designated item
6666666 V1-T6-6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 6.1Technical Data and Specifications● 10,000 amperes rms ● 60 amperes available in 6 symmetrical interrupting rating non-fusible and molded case switch 6 6● Horsepower rated ● Class H fuse clips provided● Fusible and non-fusible on fusible pullout design pullout and molded case WTST (weather-resistant/ 6 ● switch designs tamper-resistant with● 30 and 60 amperes ground fault self-test) available in fusible receptacle available 6 6DimensionsApproximate Dimensions in Inches (mm) 6Dimensions and Shipping Carton Information 6Catalog Number Carton Quantity Dimensions in Inches (mm) Height Width Depth Weight Lbs (kg) 6Metallic/Galvanized Steel Enclosure 6DPF221R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)DPF222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) 6DPU222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)DPB222R 10 8.60 (218.4) 5.30 (134.6) 3.74 (95.0) 34 (15) 6DPU222R12W 1DPU222R34W 1 1 1 14.75 (374.6) 14.75 (374.6) 12.50 (317.5) 12.50 (317.5) 4.00 (101.6) 4.00 (101.7) 6 (3) 6 (3) 6DPU222RGF20ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6DPF221RGF20ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)DPF222RGF20ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6DPU222RGF15ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)DPF221RGF15ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6DPF222RGF15ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6DPF221RGF15WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)DPF221RGF20WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6DPF222RGF15WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)DPF222RGF20WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6 6DPU222RGF15WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)DPU222RGF20WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)DPU362R 1 8.60 (218.4) 5.30 (134.6) 3.74 (94.9) 4 (2) 6Non-Metallic/Polycarbonate EnclosureACD221RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) 6ACD222RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7)ACD222URNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) 6B60NARNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 18 (8) 6Note1 Eaton Quick Pro designated item
6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-7 6.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Approximate Dimensions in Inches (mm)66 DPF221R, DPF222R, DPU222R, DPU222R12W and DPU222R34W6 4.00 (101.6)6 3.15 2.00 (80.1) (50.8)6 5.40 2.54 0.25 (137.2) (64.4) (6.4)6 1.116 1.47 (28.2) (37.2)66 5.14 (130.6)6 5.26 (133.6) 8.79 8.706 (223.4) (221.0)66 0.26 (6.5) Dia
3 Holes Req’d
6 1.65 (41.9) 1.09 (27.7)6 5.25 1.136 1.00 1.55 1.55 (133.5) (28.7) (25.4) (39.4) (39.4)6 2.39 5.10 (60.8) (129.5)6 2.97 (75.3)6 7 Knockouts for 1/2 (12.7),6 3/4 (19.1) or 1 (25.4) Conduit6 1.13 (28.7)6 1.50 0.556 (38.1) (14.0) 1.05 3.00 0.28 (7.1) Diameter6 (26.7) (76.2) Knockout—1 Req‘d
666666 V1-T6-8 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 6.1Approximate Dimensions in Inches (mm) 6ACD221RNM-A2, ACD222RNM-A2, ACD222URNM-A2 and B60NARNM-A2 6 6.26 (159.0) 4.33 (110.2) 0.90 (22.9) 6 0.20 (5.1) DIA
6 6 7.03 (178.7) 6 8.69 8.36 6(220.8) 6 (212.2) 0.21 (5.3) DIA
0.96 (24.4) 1.00 (25.4) 6 6 1 Knockout 1.35 0.81 (20.6) 1.95 1.95 6 (34.3) (49.5) (49.5) 6 for 0.50 (12.7), 1.05 1.00 (25.4), 4.08 1.83 (26.5) 1.25 (31.8) (103.6) 6.00 6(46.4) Conduit (152.4) 4.20 (106.6) 1.35 4 Knockouts for 0.75 (19.1) 6(34.3) or 1.00 (25.4) 1.36 1.76 2 Knockouts for 0.50 (12.7), Conduit 6 (34.5) (44.7) 6 0.75 (19.1) 3.52 or 1.00 (25.4) (89.3) Conduit 6DPB222R and DPU362A 6 6 6 6 6 8.60 (218.4) 6 6 6 3.74 (94.9) 6 6 6 5.30 6 (134.6) 6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-9 6.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Approximate Dimensions in Inches (mm)66 DPU222RGF20, DPF221RGF20, DPF222RGF20, DPU222RGF15, DPF221RGF15, DPF222RGF15, DPF221RGF15WTST, DPF221RGF20WTST, DPF222RGF15WTST, DPF222RGF20WTST, DPU222RGF15WTST and DPU222RGF20WTST6 6.63 (168.4)6 4.44 0.25 (6.4) Dia
(112.8)6 Hole 3 Places666 LINE LINE6 11.63 10.25 (295.4) (260.4)66 8.75 (222.3)66 2.31 (58.7) 1.44 1.186 (36.6) (30.0)6 0.75, 1.00, 1.25, 1.50 1.69 (42.9) 4.06 4.31 (19.1, 25.4, 31.8, 38.1) 0.50, 0.75, 1.00 (103.1) (109.5) 0.696 Knockouts (17.5) (12.7, 19.1, 25.4) Knockouts 20A GFCI 5.13 1.256 Receptacle (130.3) 0.50, 0.75 (31.8) (12.7, 19.1)6 6.25 (158.8) Knockouts6 0.94 (23.9)6 4.44 (112.8)6666666666 V1-T6-10 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com
Catalog 240 V 480 V Number 60 15 30 #14–4DPU362RA DPU362A Description Catalog Number Eaton Square D® GE ® Siemens® (Murray ) Milbank Midwest Metallic/Galvanized Steel Enclosure 30 A fused DPF221R — TF30R WF2030 U3830 U035F2 60 A fused DPF222R — TF60R WF2060 U3860 U065F1 60 A non-fused DPU222R — TFN60R — U3800 U065P010
Rexel Utility is the distributor of choice for investor-owned utilities (IOUs), public power municipalities, rural electrification associations (REA’s) and contractors seeking solutions for transmission, distribution and substation projects. The residential market covers new construction and upgrade projects for individual and collective housing.
Rexel Canada operates under 4 banners: Rexel Atlantic, Rexel Utility, Westburne and Nedco. You can apply to any one of these by clicking on the appropriate button down below.
Our strategy of partnering with best in class suppliers ensures our customers have access to the best products available on the market. Rexel Canada Inc. operates throughout Canada under four banners, Nedco, Westburne, Rexel Atlantic and Rexel Utility.