Volume 1 Tab 6 Rexel Cdncom

1685795677
ADVERTISEMENT
Volume 1 tab 6 rexel cdncom

File Name: DPU222RGF20WTST.pdf?i=1B332687-629E-4AF2-BE90-A4BFC8B350DE

File Size: 332.19 KB

File Type: Application/pdf

Last Modified: 5 years

Status: Available

Last checked: 9 days ago!

This Document Has Been Certified by a Professional

100% customizable

Language: English

We recommend downloading this file onto your computer

Summary

Air Conditioning Disconnects
6.1 Air Conditioning Disconnects
Air Conditioning Disconnects
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2
6
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2 6
Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-3
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-3 6
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T6-4
V1-T6-6
6
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 6
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
6
Learn 6
Online
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-1
Revision notes
Volume 1—Residential and Light Commercial, CA08100002E
Tab 6—Air Conditioning Disconnects
Revision date Section Change page(s) Description
12/20/2016 6.1 V1-T6-5–V1-T6-7 Content edits

Proof 1 — December 20, 2016 9:06 AM
6.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Contents
6 Air Conditioning Disconnects
Description Page
6 Features, Benefits and Functions . . . . . . . . . . . . . V1-T6-3
Standards and Certifications . . . . . . . . . . . . . . . . . V1-T6-3
6 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-4
Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-6
6 Technical Data and Specifications . . . . . . . . . . . . . V1-T6-7
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
6
6
6
6 Complete Line of Fused, Unfused and Molded
Case Switch Type Air Conditioning Disconnects
6
6
6 Product Description Application Description
6 An air conditioning
disconnect (ACD) is a
Fused and Non-Fused
Pullouts
The most widely used
application for ACDs is for
disconnect located between residential and light
6 a loadcenter (distribution
● ON/OFF control provided
by a pullout handle commercial air conditioning
panel) and air conditioner. units. An ACD is installed
6 Eaton’s ACD product line
● Pullout handle can be
conveniently stored in the
outdoors, in visible proximity
provides an installer or repair to the air conditioner
6 personnel with a visible
disconnecting means when
compartment in the OFF
position, helping to prevent
condensing unit. ACDs are
also found in use with heat
the handle from being
6 performing maintenance

ACDs are also known as misplaced
pumps, swimming pools,
spas, whirlpools and pump
disconnects, pullouts or air ● Protective shield cannot be houses, and meet 2008
6 conditioning switches. removed until the pullout NEC Article 422.31 (B)
handle is removed, requirements for servicing
6 Non-fused pullout and
molded case switch devices
disconnecting the power electric water heaters

Metallic enclosures are
provide personnel with a Molded Case Switch
6 visible ON-OFF disconnecting ● Rugged molded case
galvanized steel and are
installed in various locations

means. While fused pullout construction in a
6 units also perform this disconnect switch that
Non-metallic enclosures are a
plastic (polycarbonate)
function, they also provide an looks like a circuit breaker enclosure commonly used in
6 additional level of protection
for the air conditioner

but operates like an coastal or salt-water areas

ordinary household
6 Fused and non-fused devices

light switch
Plug-in molded case switch
are of a pullout design, where
6 the user physically removes
or “pulls out” a tab to break
(included) eliminates the
need for pullout handles
6 the electrical connection. No need for replacement

A molded case switch is pullout handles due to loss
similar to a light switch where or theft
6 the user “switches” the
unit to the indicated
6 ON-OFF position

6
6
6
6
V1-T6-2 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com
Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
6.1
Features, Benefits and Functions Standards and
● Single-phase, two-wire, ● Horsepower rated (10 hp Certifications 6
240 Vac and three-phase,
three-wire, 240 Vac ●
maximum at 240 Vac)
Padlockable door provision
● UL listed File No. E132354,
E143893, E196365
6
6
● NEMA 3R outdoor for safety and reduction of
enclosures offered in tampering
metallic and Metallic enclosures are
6

non-metallic versions bottom entry and exit only
● Easy-to-remove high- ● Non-metallic enclosures Contact Eaton for details
strength protective have knockouts and a hub and part numbers for CSA 6
shield for easier wiring provision for top access approved units

and mounting ● Non-metallic enclosures 6
● Easy-to-remove front cover have a single unit door and
(no screws or fasteners to
remove)
protective shield for 6
installer convenience
● 1-inch knockouts on the
bottom, back and side
● Non-metallic enclosures
are durable and provide
6
6
of unit excellent resistance to
● Copper-rated line and load climate changes
lugs that are easily Factory-installed tamper-
6

accessible resistant/weather-resistant
● Ample wiring space for receptacles are available as
mounting with a stud gun an option on some products 6
(single keyhole, two- or
three-point mounting) 6
● Fused devices are service
entrance rated 6
Note: Fused non-metallic units
require the addition of GB4NM 6
ground bar to obtain a Service
Entrance rating

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-3
6.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Product Selection
6
6 DPU222R Non-Fused Pullouts
6 Main
Ampere
Maximum hp Rating Wire Size
Range Cu/Al Catalog
Rating 120 V 240 V 60 °C or 75 °C Number
6 Galvanized Steel
6 60 —
Non-Metallic/Polycarbonate Enclosure
10 #14–3 DPU222R 1
6 60 — 10 #14–2 ACD222URNM-A2 1
6
DPF222R Fused Pullouts
6 Main
Ampere
Maximum hp Rating Wire Size
Range Cu/Al Catalog
6
Rating 120 V 240 V 60 °C or 75 °C Number
Galvanized Steel
6 30 2 2 3 #14–3 DPF221R 1
60 2 3 10 #14–3 DPF222R 1
6 Non-Metallic
30 2 3 #14–2 ACD221RNM-A2 1
6 60 3 10 #14–2 ACD222RNM-A2 1
6 For Service Entrance applications, see footnotes below

6 Molded Case Switch
DPB222R
6 Main
Ampere
Maximum hp Rating Wire Size
Range Cu/Al Catalog
Rating 120 V 240 V 60 °C or 75 °C Number
6 Galvanized Steel
6 60 — 10 #14–3 DPB222R 3
Non-Metallic/Polycarbonate Enclosure
6 60 — 10 #14–2 B60NARNM-A2 3
6 Notes
1 For replacement pullout head, order part number 96-3258-4

2 To obtain a Service Entrance Rating, the addition of a DPFG (ground bar kit) is required

6 3 For replacement molded case switch, order part number BR260NA

6
6
6
6
6
6
6
6
6
6
V1-T6-4 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com
Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
6.1
ACD with 20 Ampere Ground Fault Receptacle 1
DPU222RGF20
Main Maximum hp Rating Wire Size
6
Ampere Range Cu/Al Catalog
Rating 120 V 240 V 60 °C or 75 °C Number 6
Non-Fused Pullouts
60 — 10 #14–3 DPU222RGF20WTST 2 6
60
Fused Pullouts
— 10 #14–3 DPU222RGF20ST
6
30 2 3 #14–3 DPF221RGF20WTST 2 6
30 2 3 #14–3 DPF221RGF20ST
60 3 10 #14–3 DPF222RGF20WTST 2 6
60 3 10 #14–3 DPF222RGF20ST
6
DPU222RGF15 ACD with 15 Ampere Ground Fault Receptacle 13 6
Main
Ampere
Maximum hp Rating Wire Size
Range Cu/Al Catalog 6
Rating 120 V 240 V 60 °C or 75 °C Number
Non-Fused Pullouts 6
6
60 — 10 #14–3 DPU222RGF15ST
60 — 10 #14–3 DPU222RGF15WTST 2
Fused Pullouts
6
30 2 3 #14–3 DPF221RGF15ST
30 2 3 #14–3 DPF221RGF15WTST 2 6
60 3 10 #14–3 DPF222RGF15ST
60 3 10 #14–3 DPF222RGF15WTST 2 6
Notes
1 Factory-installed GFCI receptacle

6
6
2 Includes weather-resistant/tamper-resistant receptacles to meet 2008 NEC Article 406.8 (A) and 406.11 requirements

3 NEC permits the maximum receptacle rating of a 15 A circuit to be 15 A

6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-5
6.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Three-Phase Non-Fused ACD
6 DPU362A
Main Maximum hp Rating
Ampere Wire Size Catalog
6 Rating 240 V 480 V Range Cu 75 °C Number
60 15 30 #14–4 DPU362RA
6
6
6
Cross-Reference
6
6 Cross-Reference
6 Catalog Number
Siemens®
Description Eaton Square D® GE® (Murray®) Milbank Midwest
6 Metallic/Galvanized Steel Enclosure
6 30 A fused DPF221R — TF30R WF2030 U3830 U035F2
60 A fused DPF222R — TF60R WF2060 U3860 U065F1
6 60 A non-fused DPU222R — TFN60R — U3800 U065P010
6
60 A non-fused compact design DPU222R — — WNFC2060 — —
60 A molded case switch DPB222R QO200TR TNA60R1 WNAS2060 — U065NA1
6 60 A non-fused with ground fault receptacle DPU222RGF20ST — TFN60RGFR WN2060GFCI U3822-20GR U065P010
30 A fused with ground fault receptacle DPF221RGF20ST — — WF2030GFCI — U035F010
6 60 A fused with ground fault receptacle DPF222RGF20ST — — WF2060GFCI — U065F010
DPU222R12W 1
6
60 A non-fused with 1/2-inch wire harness — — — — —
60 A non-fused with 3/4-inch wire harness DPU222R34W 1 — — — — —
6 60 A three-phase 600 V molded case switch DPU362RA — — — — U0653F
Non-Metallic/Polycarbonate Enclosure
6 30 A fused ACD221RNM-A2 — TPF30R WF2030PL — P035F
60 A fused ACD222RNM-A2 — TPF60R WF2060PL — P065F
6 60 A non-fused ACD222URNM-A2 — TPN60R1 WN2060PL — P065P1
6 60 A molded case switch B60NARNM-A2 QO200TRNM TPNA60R1 WNAS2060PL — P065NA1
30 A fused with 15 A ground fault receptacle DPF221RGF15WRTRST — — — — —
6 30 A fused with 20 A ground fault receptacle DPF221RGF20WRTRST — — — — —
60 A fused with 15 A ground fault receptacle DPF222RGF15WRTRST — — — — —
6 60 A fused with 20 A ground fault receptacle DPF222RGF20WRTRST — — — — —
6
60 A non-fused with 15 A ground fault receptacle DPU222RGF15WRTRST — — — — —
60 A non-fused with 20 A ground fault receptacle DPU222RGF20WRTRST — — — U3822-20GWR —
6 Note
1 Eaton Quick ProSM designated item

6
6
6
6
6
6
6
V1-T6-6 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com
Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
6.1
Technical Data and Specifications
● 10,000 amperes rms ● 60 amperes available in
6
symmetrical interrupting
rating
non-fusible and molded
case switch 6
6
● Horsepower rated ● Class H fuse clips provided
● Fusible and non-fusible on fusible pullout design
pullout and molded case WTST (weather-resistant/
6

switch designs tamper-resistant with
● 30 and 60 amperes ground fault self-test)
available in fusible receptacle available 6
6
Dimensions
Approximate Dimensions in Inches (mm) 6
Dimensions and Shipping Carton Information 6
Catalog Number
Carton
Quantity
Dimensions in Inches (mm)
Height Width Depth Weight Lbs (kg)
6
Metallic/Galvanized Steel Enclosure
6
DPF221R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)
DPF222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) 6
DPU222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)
DPB222R 10 8.60 (218.4) 5.30 (134.6) 3.74 (95.0) 34 (15) 6
DPU222R12W 1
DPU222R34W 1
1
1
14.75 (374.6)
14.75 (374.6)
12.50 (317.5)
12.50 (317.5)
4.00 (101.6)
4.00 (101.7)
6 (3)
6 (3)
6
DPU222RGF20ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6
DPF221RGF20ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF222RGF20ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6
DPU222RGF15ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF221RGF15ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
6
DPF222RGF15ST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
6
DPF221RGF15WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF221RGF20WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6
DPF222RGF15WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF222RGF20WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 6
6
DPU222RGF15WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPU222RGF20WTST 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPU362R 1 8.60 (218.4) 5.30 (134.6) 3.74 (94.9) 4 (2)
6
Non-Metallic/Polycarbonate Enclosure
ACD221RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) 6
ACD222RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7)
ACD222URNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7)
6
B60NARNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 18 (8)
6
Note
1 Eaton Quick Pro designated item

6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-7
6.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Approximate Dimensions in Inches (mm)
6
6 DPF221R, DPF222R, DPU222R, DPU222R12W and DPU222R34W
6 4.00
(101.6)
6 3.15 2.00
(80.1) (50.8)
6 5.40 2.54 0.25
(137.2) (64.4) (6.4)
6
1.11
6
1.47
(28.2)
(37.2)
6
6 5.14
(130.6)
6 5.26
(133.6)
8.79 8.70
6 (223.4) (221.0)
6
6 0.26 (6.5) Dia

3 Holes Req’d

6 1.65
(41.9) 1.09
(27.7)
6
5.25 1.13
6
1.00 1.55 1.55
(133.5) (28.7) (25.4) (39.4) (39.4)
6
2.39 5.10
(60.8) (129.5)
6 2.97
(75.3)
6
7 Knockouts for 1/2 (12.7),
6 3/4 (19.1) or 1 (25.4) Conduit
6 1.13
(28.7)
6
1.50 0.55
6 (38.1) (14.0)
1.05 3.00 0.28 (7.1) Diameter
6 (26.7) (76.2) Knockout—1 Req‘d

6
6
6
6
6
6
V1-T6-8 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com
Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
6.1
Approximate Dimensions in Inches (mm)
6
ACD221RNM-A2, ACD222RNM-A2, ACD222URNM-A2 and B60NARNM-A2
6
6.26
(159.0)
4.33
(110.2)
0.90
(22.9)
6
0.20
(5.1) DIA

6
6
7.03
(178.7) 6
8.69
8.36
6
(220.8)
6
(212.2) 0.21
(5.3)
DIA

0.96
(24.4)
1.00
(25.4) 6
6
1 Knockout 1.35
0.81
(20.6) 1.95 1.95
6
(34.3) (49.5) (49.5)
6
for 0.50 (12.7),
1.05
1.00 (25.4), 4.08
1.83 (26.5)
1.25 (31.8) (103.6) 6.00
6
(46.4) Conduit (152.4)
4.20
(106.6)
1.35
4 Knockouts
for 0.75 (19.1) 6
(34.3) or 1.00 (25.4)
1.36 1.76
2 Knockouts
for 0.50 (12.7),
Conduit
6
(34.5) (44.7)
6
0.75 (19.1)
3.52 or 1.00 (25.4)
(89.3) Conduit
6
DPB222R and DPU362A
6
6
6
6
6
8.60
(218.4)
6
6
6
3.74
(94.9) 6
6
6
5.30 6
(134.6)
6
Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com V1-T6-9
6.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Approximate Dimensions in Inches (mm)
6
6 DPU222RGF20, DPF221RGF20, DPF222RGF20, DPU222RGF15, DPF221RGF15, DPF222RGF15, DPF221RGF15WTST,
DPF221RGF20WTST, DPF222RGF15WTST, DPF222RGF20WTST, DPU222RGF15WTST and DPU222RGF20WTST
6 6.63
(168.4)
6 4.44
0.25 (6.4) Dia

(112.8)
6 Hole 3 Places
6
6
6
LINE LINE
6 11.63 10.25
(295.4) (260.4)
6
6 8.75
(222.3)
6
6 2.31
(58.7) 1.44 1.18
6 (36.6) (30.0)
6 0.75, 1.00, 1.25, 1.50
1.69
(42.9)
4.06 4.31
(19.1, 25.4, 31.8, 38.1) 0.50, 0.75, 1.00 (103.1) (109.5)
0.69
6 Knockouts (17.5) (12.7, 19.1, 25.4)
Knockouts
20A GFCI 5.13 1.25
6 Receptacle (130.3)
0.50, 0.75
(31.8)
(12.7, 19.1)
6 6.25
(158.8)
Knockouts
6 0.94
(23.9)
6 4.44
(112.8)
6
6
6
6
6
6
6
6
6
6
V1-T6-10 Volume 1—Residential and Light Commercial CA08100002E—December 2016 www.eaton.com

Catalog 240 V 480 V Number 60 15 30 #14–4DPU362RA DPU362A Description Catalog Number Eaton Square D® GE ® Siemens® (Murray ) Milbank Midwest Metallic/Galvanized Steel Enclosure 30 A fused DPF221R — TF30R WF2030 U3830 U035F2 60 A fused DPF222R — TF60R WF2060 U3860 U065F1 60 A non-fused DPU222R — TFN60R — U3800 U065P010

Download Now

Documemt Updated

ADVERTISEMENT

Popular Download

ADVERTISEMENT

Frequently Asked Questions

What is rexel utility?

Rexel Utility is the distributor of choice for investor-owned utilities (IOUs), public power municipalities, rural electrification associations (REA’s) and contractors seeking solutions for transmission, distribution and substation projects. The residential market covers new construction and upgrade projects for individual and collective housing.

How do i apply to rexel canada?

Rexel Canada operates under 4 banners: Rexel Atlantic, Rexel Utility, Westburne and Nedco. You can apply to any one of these by clicking on the appropriate button down below.

What is the rexel canada strategy?

Our strategy of partnering with best in class suppliers ensures our customers have access to the best products available on the market. Rexel Canada Inc. operates throughout Canada under four banners, Nedco, Westburne, Rexel Atlantic and Rexel Utility.