MINIMED™ 770G SYSTEM | CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDESTART HERE1 2 3 4 Wash your hands. Select Reservoir & Tubing. Select New Reservoir. Remove the infusion set you have been using by Press . Select Options. loosening the adhesive and pulling away from body
5 6 Remove the used reservoir from the pump. Select Rewind
FILL RESERVOIR & CONNECT TO THE INFUSION SET TUBINGFollow the next steps to fill reservoir with insulin and connect to the infusion set tubing
1 Plunger 2 3 Transfer 4 rod guard Reservoir Transfer Plunger Insulin guard vial Remove from package. Make sure Pull plunger down to Wipe vial with alcohol. Place Push and hold insulin vial is at room temperature the amount that you vial on table. Firmly press the plunger down
to reduce the risk of air bubbles. plan to fill with insulin. blue transfer guard onto vial
1 Continued on next page MINIMED™ 770G SYSTEM | CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDE WARNING If insulin or any liquid gets inside the tubing connector, it can temporarily block the vents that allow the pump to properly fill the infusion set. This may result in the delivery of too little or too much insulin, which could cause hyperglycaemia or hypoglycaemia
5 6 7 8 With your thumb still on the plunger, Tap the reservoir to move If needed, pull plunger To avoid getting insulin on the top of the flip over so vial is on top. Release air bubbles to top of back down to amount reservoir, turn vial over so it is upright. Hold thumb and pull plunger down to fill reservoir. Push plunger of insulin needed for transfer guard and turn reservoir counter- with insulin. up to move air into vial. 2-3 days. clockwise and remove from transfer guard
CONNECT RESERVOIR TO INFUSION SETYou will place the tubing connector onto the end of the infusion set to the filled reservoir
1 Quick-serter® Tubing connector 2 3 4 Release Quick-set ® button Needle guard Green side Green side button button Blue hub Hub handle Tubing slot Gently push the tubing If you see air bubbles, tap Twist plunger counter- Remove infusion set from package. Remove connector onto reservoir. reservoir to move them to clockwise to loosen the paper that holds the tubing together. Turn clockwise until locked. top. Push plunger just a bit to and remove
You will hear a click. move them into tubing
THE BACKLIGHT MAY HAVE TURNED OFF Press any button to turn the screen back on
Press to open the menu. If the pump Select Load Reservoir Select Next
is locked, you will need to unlock the from the menu. 2 pump after pressing . Continued on next page MINIMED™ 770G SYSTEM | CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDEPLACE RESERVOIR INTO PUMPNow place the filled reservoir into the reservoir compartment of the pump
1 2 3 Place reservoir into pump. Turn clockwise until you feel Select Next
reservoir lock into place
LOAD RESERVOIR AND FILL TUBINGFollow these steps to load the reservoir and fill the tubing
1 2 3 4 Drops at end of tubing Select Load and keep When you see this screen, Select Fill and keep holding until you see After you see drops, holding . select Next. drops at the end of tubing, then let go. press and select Next
INSERT INFUSION SETNext, follow the steps to insert the infusion set into your body
1 2 3 Place the MiniMed Quick-serter Use two fingers to seat the Peel the paper from the insertion device onto a sturdy flat infusion set inside the serter adhesive on both sides surface with handle facing down. securely and gently push down. of the needle guard
Place blue hub into serter, placing 3 the handle in the tubing slot. Continued on next page MINIMED™ 770G SYSTEM | CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDE4 5 6 Pull green handle down The best areas of the body to insert the infusion set are Turn to loosen needle until it clicks. The two shown in the shaded areas of this drawing. Choose areas guard and pull
green side buttons will that are away from the natural bend of your waist or belt also click into place. Do line of your pants. Avoid areas of hard or scar tissue. Consult not press the green side with your healthcare provider on appropriate areas to insert buttons at this time. your infusion set. Wipe with alcohol or other antiseptic
7 8 9 10 Hold serter against Press the two green side Press down the release Pull serter away from body. Press cleaned site. buttons at the same time. button of the serter to adhesive against skin
If they are not pressed at the release the infusion set
same time the infusion set will not insert properly
11 12 1 Dispose blue handle into a sharps 2 container
Hold infusion set. Pull blue handle straight out Fold blue handle to remove needle. until locked
4 Continued on next page MINIMED™ 770G SYSTEM | CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDEFILL CANNULAYou will now fill the cannula, the little tube under your skin, with insulin
1 2 NOTE: Your pump will remember the Fill amount that you used last. Always verify that the Fill amount is correct
If it is correct, press to Fill Now and press
If it is incorrect, press . Change to correct amount and press . Select Fill Now
Select Fill. Select Fill amount and enter : 0.300 if using 6mm cannula 0.500 if using 9mm cannula Then press
3 4 NOTE: Select Stop Filling if you need to stop, for example, if you notice the Total amount is incorrect. This should rarely happen if you have verified the Fill amount on the previous screen
Select Fill Now. The Home screen displays the insulin as it fills the cannula
Your infusion set change is now complete!Always read instructions for use©2020 Medtronic MiniMed, Inc. All rights reserved. Medtronic Australasia Pty Ltd. 2 Alma Road, Macquarie Park. NSW 2113. Australia. medtronic-diabetes.com.au 8339-082020 5
0.300 if using 6mm cannula 0.500 if using 9mm cannula Then press . The Home screen displays the insulin as it fills the cannula. Your infusion set change is now complete! Medtronic …
The MiniMed™ Quick-set™ infusion set provides the convenience of a disconnect at the infusion site and a pre-attached adhesive for a discreet, low profile design. Warning! Please Try Again Later.
The MiniMed ™ Quick-serter ™ device is the one used with the MiniMed ™ Quick-set ™ infusion set and helps to make consistent insertions with just the press of a button. The MiniMed ™ Silhouette ™ infusion set is a soft cannula infusion set that can be inserted at a variety of angles.
Designed for Every Body and Every Lifestyle. An infusion set includes the thin plastic tubing that delivers insulin from the pump to your body. The MiniMed Quick-set infusion set is our most popular infusion set. The MiniMed Quick-set is available in four tubing lengths and two cannula lengths.
This infusion set has a 90°, soft cannula and can be inserted with only 4 steps. The all-in-one insertion design means that no separate serter is needed. The MiniMed ™ Mio ™ Advance infusion set can be inserted with one hand (left or right) and has a hidden needle throughout insertion.