Specification Manual Ground Source Heat Pumps XTERRA SERIES FORCAIR RAVE/ RAHE 36 THRU 70 FORCAIR2 RTVE/ RTHE 30 THRU 60 AQUA2 RAWE/CDWE 36 THRU 140 SOURC3 RMVE/ RMHE 36 THRU 70 Rev 9 Mar-27-09 DESCRIPTIONS RESIDENTIAL MODEL # DESCRIPTION RA VE 502 - C 1 3 1UNIT DESIGNATION POWER SUPPLYR=RESIDENTIAL 1=208/230V 1Ph 2=208/230V 3Ph 3=575V 3Ph 4=460/480V 3PHUNIT TYPE 5=220/240V 1PH 50HZA=STANDARD 6=380V 3PH 50HZM=MULTID=DUAL COMPRESSORS=SPECIALW=HEAT ONLY BLOWER TYPET=TWO SPEED 1=NoneP=MINI 2=Standard PSC 3 Speed Blower 3=ECM BlowerUNIT STYLEW=HYDRONICV=VERTICALD=DOWNFLOW CONFIGURATIONH=HORIZONTAL 1=LEFT SIDE RETURN (STD)S=SPLIT 2=RIGHT SIDE RETURN 3=NONEREFRIGERANT TYPEE=R410A REFRIGERANTF=R22 REFRIGERANT HEAT EXCHANGERNORMAL SIZE C=COPPERX 1000 BTU/H F=S.S. FLATPLATE H=CUPRO HYDRONIC LOOP N=CUPRO NICKELDESUPERHEATER OPTION1=NONE2=PARTIAL DESUPERHEATER3=FULL TIME SERIAL # DESCRIPTION XL 08 01 A 1000 ABILL OF MFG MFG LOCATION A=SOUTH RAILWAY PLANTYEAR OF MFG SEQUENTIAL NUMBERMONTH OF MFG FUTURE USE A=LINE NUMBER DESCRIPTIONS COMMERCIAL MODEL # DESCRIPTION CD WE 114 2 - C 1 1 UNIT DESIGNATION C=COMMERCIAL POWER SUPPLY 1=208/230V 1Ph 2=208/230V 3Ph 3=575V 3Ph 4=460/480V 3PHUNIT TYPE 5=220/240V 1PH 50HZA=STANDARD 6=380V 3PH 50HZM=MULTID=DUAL COMPRESSORS=SPECIAL BLOWER TYPEW=HEAT ONLY 1=NoneT=TWO SPEED 2=Standard PSC 3 Speed BlowerP=MINI 3=ECM BlowerUNIT STYLEW=HYDRONICV=VERTICALD=DOWNFLOW HEAT EXCHANGERH=HORIZONTAL C=COPPERS=SPLIT F=S.S. FLATPLATE H=CUPRO HYDRONIC LOOPREFRIGERANT TYPE N=CUPRO NICKELE=R410A REFRIGERANTF=R22 REFRIGERANTNORMAL SIZE DESUPERHEATER OPTIONX 1000 BTU/H 1=NONE 2=PARTIAL DESUPERHEATER 3=FULL TIME SERIAL # DESCRIPTION XL 08 01 A 1000 A BILL OF MFG MFG LOCATION A=SOUTH RAILWAY PLANT YEAR OF MFG SEQUENTIAL NUMBER MONTH OF MFG FUTURE USE A=LINE NUMBER Single Compressor Single Capacity RAVE 36 Data SheetElectrical Specification Mechanical Specifications Compressor Blower Loop Pump Without pumps Refrigerant: R-410A Voltage Elect. Total Min. Max. Fuse/ Air Coil Symbol RLA LRA FLA HP FLA HP FLA Ampac Breaker Square Rows Tube Fins/ 208/230-1-60 1 20 112 4.3 .5 2.2 1/3 24.3 29.3 40 Feet Deep O.D. Inch 575-3-60 3 5.7 34.1 4.3 .5 - - 10 11.4 15 2.78 5 0.375 12 *HACR - type breaker per NEC Water Coil Type Working Press Canister 600 psig Blower Size Comp. Type 9x9 ScrollBlower Performance Net Weight Shipping Weight Static 305 355 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure CFM 1200 1100 1060 1020 975 950 885ISO 13256-1 Performance Data Rated at 1100 CFM and 7.0 GPM Ground Water Ground Loop Cooling Heating Cooling HeatingCapacity EER Capacity COP Capacity EER Capacity COP 35,300 19.9 34,700 4.3 46,600 13.3 31,100 3.0Capacity Data All performance at 1100 CFM and 7.0 GPMHEATING COOLINGEntering Total Entering Total Power Fluid Entering Air Capacity Fluid Entering Air Capacity Power input COP EER Temp
T Temp (oF) (BtuH) (B H) Temp
T Temp (oF) H) iinputt (kW) (BtuH) (B (kW) (oF) Stage 1 (oF) Stage 1 25 32000 2.1 4.4 25 27900 1.8 22.7 30 33400 2.1 4.6 30 27100 1.8 21.8 40 34000 2.2 4.5 40 26900 1.8 21.0 50 37900 2.2 5.0 50 26200 1.8 20.2 60 60o 41600 2.4 5.1 60 60o 25300 2.0 17.6 70 46100 2.5 5.4 70 24800 2.2 14.3 80 47300 2.7 5.2 80 25900 2.4 12.6 90 48100 2.8 5.1 90 27000 2.7 9.2 25 31400 2.3 2.7 25 34400 1.9 21.3 30 32700 2.3 2.8 30 33500 1.9 20.5 40 33400 2.4 3.2 40 33200 2.0 19.8 50 37100 2.4 3.6 50 32300 2.0 19.0 60 68o 40800 2.6 4.3 60 68o 31200 2.2 16.6 70 45200 2.7 4.4 70 30600 2.3 13.4 80 46400 2.9 4.3 80 32000 2.6 11.9 90 47200 3.0 5.2 90 33300 2.9 8.7 25 29200 2.4 3.6 25 43600 2.1 27 30 30400 2.4 3.8 30 42400 2.1 26 40 31000 2.5 3.7 40 42000 2.2 25 50 34500 2.5 4.1 50 40900 2.2 24 60 80o 37900 2.7 4.2 60 80o 39500 2.4 21 70 42000 2.8 4.4 70 38700 2.6 17 80 43200 3.0 4.3 80 40500 2.9 15 90 43900 3.1 4.2 90 41200 3.2 11 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Single Capacity RAVE 50 Data SheetElectrical Specification Mechanical Specifications Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Total Min. Max. Fuse/ Air Coil Symbol RLA LRA FLA* HP* FLA HP FLA Ampac. Breaker Square Rows Tube Fins/ 208/230-1-60 1 30 145 4.3 .75 2.2 0.3 34.3 41.8 60 Feet Deep O.D. Inch 3.88 5 0.375 12 Water Coil Type Working Press Canister 600 psig Blower Size Comp. TypeBlower Performance 10 x 10 Scroll Static Net WEIGHT Shipping Weight 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure 320 340 CFM 1640 1550 1495 1440 1390 1360 1290ISO 13256-1 Performance Data Rated at 1550 CFM and 13.0GPM Ground Water Ground Loop Cooling Heating Cooling HeatingCapacity EER Capacity COP Capacity EER Capacity COP 48,900 20.2 45,600 4.1 47,000 11.5 36,000 2.9Capacity Data All performance rated at 1550 CFM and 10.0 GPMHEATING COOLINGEntering Total Entering Total Power Fluid Entering Air Capacity Fluid Entering Air Capacity Power input COP EER Temp. Temp (oF) (BtuH) Temp. Temp (oF) (BtuH) input (kW) (kW) (oF) Stage 1 (oF) Stage 1 25 43500 2.6 4.9 25 36400 1.6 23.4 30 45400 2.8 4.7 30 35400 1.6 22.6 40 46300 3.0 4.5 40 35100 1.7 21.0 50 51600 3.2 4.7 50 34200 1.9 18.3 60 60o 56600 3.3 5.0 60 60o 33000 2.0 16.5 70 62700 3.4 5.4 70 32400 2.4 13.5 80 64400 3.4 5.5 80 33800 3.0 11.1 90 65500 3.6 5.3 90 35300 3.9 9.1 25 42700 4.2 3.0 25 44900 2.0 22.0 30 44500 4.1 3.2 30 43700 2.1 21.2 40 45500 3.4 3.9 40 43300 2.2 19.7 50 50500 3.4 4.3 50 42200 2.4 17.2 60 68o 55500 3.6 4.5 60 68o 40700 2.6 15.5 68 61500 3.9 4.6 68 40000 3.2 12.7 80 63200 3.8 4.9 80 41800 4.0 10.5 90 64200 3.9 4.8 90 43500 5.1 8.6 25 39700 2.9 4.0 25 56900 2.0 27.8 30 41400 3.1 3.9 30 55400 2.1 26.9 40 42200 3.3 3.7 40 54800 2.2 25.0 50 47000 3.6 3.9 50 53400 2.5 21.8 60 80o 51600 3.7 4.1 60 80o 51600 2.6 19.6 70 57200 3.8 4.4 70 50500 3.2 16.0 80 58800 3.8 4.5 80 52900 4.0 13.2 90 59800 4.0 4.4 90 53800 5.0 10.8 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Single Capacity RAVE 57 Data SheetElectrical Specification Mechanical Specifications Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Total Min. Max. Fuse/ Air Coil Symbol RLA LRA FLA HP FLA HP FLA Ampac Breaker* Square Rows Tube Fins/ 208/230-1-60 1 33.6 158 5.0 0.75 2.2 1/6(x2) 38.6 47.0 70 Feet Deep O.D. Inch 575-3-60 3 8.6 54 2.2 0.75 - - 10.8 13.6 15 3.88 5 0.375 12 *HACR - type breaker per NEC Water Coil Type Working Press Canister 600 psig Blower Size Comp. Type 10 x 10 ScrollBlower Performance Net Weight Shipping Weight Static 340 365 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure CFM 1800 1700 1640 1580 1525 1490 1410ISO 13256-1 Performance Data Rated at 1700 CFM and 14.0GPM Ground Water Ground Loop Cooling Heating Cooling HeatingCapacity EER Capacity COP Capacity EER Capacity COP 53,600 20.4 51,300 4.2 62,400 11.6 44,700 3.2Capacity Data All performance rated at 1700 CFM and 13.0 GPMHEATING COOLING 57000EnteringE t i Total T t l Entering E t i T t l Total Power Power Fluid Entering Air Capacity Fluid Entering Air Capacity input COP input EER Temp. Temp (oF) (BtuH) Temp. Temp (oF) (BtuH) (kW) (kW) (oF) Stage 1 (oF) Stage 1 25 49600 3.2 4.5 25 43300 1.8 23.9 30 51800 3.5 4.4 30 42100 1.8 23.0 40 52700 3.7 4.2 40 41700 2.0 21.4 50 58800 4.0 4.4 50 40700 2.2 18.7 60 60o 64500 4.1 4.6 60 60o 39300 2.3 16.8 70 71500 4.2 5.0 70 38500 2.8 13.7 80 73400 4.2 5.1 80 40200 3.5 11.4 90 74600 4.4 4.9 90 41900 4.5 9.3 25 48700 5.1 2.8 25 53400 2.4 22.5 30 50700 5.0 3.0 30 52000 2.4 21.7 40 51800 4.2 3.6 40 51500 2.6 20.1 50 57600 4.2 4.0 50 50100 2.9 17.6 60 68o 63300 4.4 4.2 60 68o 48400 3.1 15.8 68 70100 4.8 4.3 68 47500 3.7 12.9 80 72000 4.6 4.6 80 49700 4.6 10.7 90 73200 4.8 4.5 90 51700 5.9 8.7 25 45300 3.6 3.7 25 67700 2.4 28.4 30 47200 3.8 3.6 30 65700 2.4 27.4 40 48100 4.1 3.4 40 65200 2.6 25.5 50 53500 4.4 3.6 50 63500 2.9 22.2 60 80o 58800 4.5 3.8 60 80o 61300 3.1 20.0 70 65200 4.7 4.1 70 6010 3.7 16.4 80 67000 4.7 4.2 80 62800 4.6 13.5 90 68100 4.9 4.0 90 63900 5.8 11.1 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Single Capacity RAVE 70 Data SheetElectrical Specification Mechanical Specifications Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Min Max. Fuse/ Air Coil Symbol RLA LRA FLA* HP* FLA HP FLA Circuit Breaker Square Rows Tube Fins/ 208/230-1-60 1 35.7 148 5 .75 2.2 0.3 40.7 49.6 70 Feet Deep O.D. Inch 3.88 5 0.375 12 Water Coil Type Working Press Brazed Plate 600 psigBlower Performance Blower Size Comp. Type Static 10 x 10 Scroll 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure Net WEIGHT Shipping Weight CFM 2020 1900 1840 1770 1710 1670 1580 355 380ISO 13256-1 Performance Data Rated at 1900 CFM and 15.0GPM Ground Water Ground Loop Cooling Heating Cooling HeatingCapacity EER Capacity COP Capacity EER Capacity COP 73,300 20.6 63,900 4.1 72,400 10.0 57,400 3.0Capacity Data All performance rated at 1900 CFM and 15.0 GPMHEATING COOLINGEntering Total Entering Power Total Fluid Entering Air p Capacityy Fluid Entering Air Power input COP Capacity EER Temp. Temp (oF) (BtuH) Temp. Temp (oF) input (kW) (kW) (BtuH) (oF) Stage 1 (oF) 25 60395 3.6 4.9 25 53200 2.2 24.1 30 62900 3.9 4.7 30 51600 2.2 23.3 40 64100 4.2 4.5 40 51300 2.4 21.6 50 71500 4.5 4.7 50 49900 2.6 18.9 60 60o 78500 4.6 5.0 60 60o 48200 2.8 17.0 70 87000 4.8 5.4 70 47300 3.4 13.9 80 89200 4.7 5.5 80 49300 4.3 11.5 90 90700 5.0 5.3 90 51500 5.5 9.4 25 59200 5.8 3.0 25 65600 2.9 22.7 30 61700 5.6 3.2 30 63800 2.9 21.9 40 63000 4.7 3.9 40 63300 3.1 20.3 50 70000 4.8 4.3 50 61500 3.5 17.8 60 68o 77000 5.0 4.5 60 70o 59500 3.7 16.0 70 85300 5.4 4.6 68 58300 4.5 13.1 80 87500 5.2 4.9 80 61000 5.6 10.8 90 89000 5.4 4.8 90 63500 7.2 8.8 25 55100 4.0 4.0 25 83100 2.9 28.7 30 57300 4.3 3.9 30 80800 2.9 27.7 40 58500 4.6 3.7 40 80000 3.1 25.7 50 65100 5.0 3.9 50 77900 3.5 22.5 60 80o 71500 5.1 4.1 60 80o 75300 3.7 20.2 70 79200 5.3 4.4 70 73700 4.5 16.5 80 81500 5.3 4.5 80 77200 5.6 13.7 90 82800 5.6 4.4 90 78300 7.0 11.2 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Dual Capacity RTVE 30 Data SheetElectrical Specification Mechanical Specifications Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Total Min. Max. Fuse/ Air Coil Symbol RLA LRA FLA* HP* FLA HP FLA Ampac. Breaker Square Rows Tube Fins/ 208/230-1-60 1 19 82 4.3 .75 2.2 1/3 23.3 28.1 40 Feet Deep O.D. Inch 3.88 5 0.375 12Blower Performance Water Coil Type Working Press Static 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure Canister 600 psig CFM 1020 980 898 865 832 796 775 Blower Size Comp. Type 10 x 10 ScrollARI 13256-1 FULL LOAD Performance Data Rated at 1000 CFM and 7.0 GPM Net WEIGHT Shipping WeightPART LOAD Performance Data Rated at 700 CFM and 7.0 GPM 305 355GWHP 50F EWT HEATING 60F EWT COOLING
Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 228,230 31,400 22.9 15.45 21,880 31,200 3.9 3.9GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F COOLING Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 226,700 34,100 23.0 15.5 16,800 24,000 3.3 3.2Capacity Data All performance at 700 CFM 1st stage; 980 CFM 2nd stage and 7.0 GPMHEATING COOLINGEntering Total Power Total Power Entering Total Power Total Power Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity input EER Capacity input EER COP COP Temp. Temp (oF) (BtuH) (kW) (BtuH) (kW) Temp. Temp (oF) (BtuH) (kW) Stage 1 (BtuH) (kW) Stage 2 o o ( F) Stage 1 Stage 1 Stage 2 Stage 2 ( F) Stage 1 Stage 1 Stage 2 Stage 2 25 17200 1.3 13 4.0 40 22700 1.7 17 3.9 39 25 28400 1.0 10 27.6 27 6 35800 1.9 19 20.9 20 9 30 19000 1.4 4.1 25300 1.9 4.0 30 28100 1.1 26.5 35600 2.0 19.8 40 22000 1.5 4.3 29400 2.1 4.2 40 27700 1.1 25.5 33900 2.0 18.8 50 o 26100 1.7 4.4 34400 2.4 4.3 50 o 24300 1.0 24.4 29800 2.4 13.9 60 60 29100 1.9 4.6 38400 2.5 4.5 60 60 21400 1.0 22.3 25500 2.2 12.7 70 33300 2.0 4.8 44000 2.8 4.7 70 20900 1.1 19.5 22400 1.8 13.4 80 34600 2.1 4.8 45600 2.9 4.7 80 18500 1.1 16.7 20800 1.7 13.4 90 35000 2.0 5.1 46200 2.7 4.9 90 18000 1.3 13.6 20200 1.9 12.0 25 16800 1.3 3.9 19900 1.5 3.8 25 35000 1.1 33.1 44200 2.0 19.7 30 18800 1.4 4.0 21300 1.6 3.9 30 34700 1.0 33.1 44000 2.1 18.7 40 21900 1.5 4.2 25000 1.8 4.0 40 34200 1.1 32.3 41800 2.1 17.7 50 25600 1.8 4.3 28100 2.0 4.1 50 29900 1.0 29.1 36800 2.5 13.1 60 70 28600 1.9 4.5 35700 2.4 4.3 60 70 26400 1.0 26.5 31500 2.4 11.9 70 32700 2.1 4.7 39300 2.6 4.5 70 25800 1.1 23.2 27700 2.0 12.6 80 33900 2.1 4.7 43600 2.8 4.5 80 22900 1.2 19.9 25600 1.8 12.6 90 34300 2.0 4.9 46400 2.8 4.8 90 22200 1.4 16.2 24900 2.0 11.3 25 15600 1.2 3.8 16800 1.3 3.7 25 44300 0.9 32.8 56000 2.2 24.9 30 17500 1.3 3.9 19800 1.5 3.8 30 43900 0.9 31.5 55700 2.4 23.6 40 20300 1.4 4.1 23300 1.7 4.0 40 43300 1.0 30.3 52900 2.4 22.4 50 23800 1.7 4.2 27100 1.9 4.1 50 37900 1.2 29.1 46600 2.8 16.6 60 80o 26600 1.8 4.4 33200 2.3 4.3 60 80o 33400 1.3 26.5 39800 2.6 15.1 70 30400 1.9 4.6 36600 2.4 4.5 70 32700 1.4 23.2 35000 2.2 16.0 80 31500 2.0 4.6 40500 2.7 4.5 80 29000 1.5 19.9 32500 2.0 15.9 90 31900 1.9 4.9 43100 2.7 4.7 90 28100 1.7 16.2 31500 2.2 14.3 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Dual Capacity RTVE 40 Data SheetElectrical Specification Mechanical Specifications Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Total Min. Max. Fuse/ Air Coil Symbol RLA LRA FLA* HP* FLA HP FLA Ampac. Breaker Square Rows Tube Fins/ 208/230-1-60 1 24 96 4.3 .75 2.2 1/3 34.3 34.3 50 Feet Deep O.D. Inch 3.88 5 0.375 12Blower Performance Water Coil Type Working Press Static 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure Canister 600 psig CFM 1250 1200 1100 1060 1020 975 950 Blower Size Comp. Type 10 x 10 ScrollARI 13256-1 FULL LOAD Performance Data Rated at 1300 CFM and 9.0 GPM Net WEIGHT Shipping WeightPART LOAD Performance Data Rated at 1100 CFM and 9.0 GPM 325 375GWHP 50F EWT HEATING 60F EWT COOLING
Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 236,550 45,920 23.4 19.0 28,900 43,770 3.8 3.8GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F COOLING Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 237,500 46,200 20.6 14.7 28,000 34,600 3.6 3.2Capacity Data All performance at 750 CFM 1st stage; 1200 CFM 2nd stage and 9.0 GPMHEATING COOLINGEntering Total Power Total Power Entering Total Power Total Power Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity input EER Capacity input EER COP COP Temp. Temp (oF) (BtuH) (kW) (BtuH) (kW) Temp. Temp (oF) (BtuH) (kW) Stage 1 (BtuH) (kW) Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2 25 20400 1.5 4.0 28100 2.1 3.9 25 22000 0.8 27.6 27400 1.4 20.9 30 24500 1.7 4.1 33200 2.4 4.0 30 22000 0.8 26.5 27100 1.5 19.8 40 30100 21 2.1 43 4.3 39000 27 2.7 42 4.2 40 21500 08 0.8 25 5 25.5 26400 15 1.5 18 8 18.8 50 35200 2.3 4.4 45400 3.1 4.3 50 21000 0.9 24.4 25600 2.0 13.9 60 60o 39300 2.5 4.6 55600 3.7 4.5 60 60o 20300 0.9 22.3 24300 2.1 12.7 70 46700 2.9 4.8 61200 3.9 4.7 70 19600 1.0 19.5 24100 2.0 13.4 80 50000 3.1 4.8 67800 4.3 4.7 80 19000 1.1 16.7 25800 2.1 13.4 90 54600 3.1 5.1 72200 4.3 4.9 90 17400 1.3 13.6 27000 2.5 12.0 25 20000 1.5 3.9 27500 2.1 3.8 25 27100 0.8 32.9 33800 1.5 19.7 30 24000 1.8 4.0 32500 2.5 3.9 30 27000 0.8 33.0 33500 1.6 18.7 40 29500 2.1 4.2 38200 2.8 4.0 40 26500 0.8 32.1 32600 1.7 17.7 50 34500 2.4 4.3 44500 3.2 4.1 50 25900 0.9 28.9 31600 2.2 13.1 60 70 38500 2.5 4.5 54500 3.7 4.3 60 70 25000 1.0 26.3 30000 2.3 11.9 68 45800 2.9 4.7 60000 3.9 4.5 68 24200 1.1 23.0 29700 2.1 12.6 80 49000 3.1 4.7 66500 4.3 4.5 80 23400 1.2 19.7 31900 2.3 12.6 90 53500 3.2 4.9 70800 4.3 4.8 90 21500 1.3 16.1 33300 2.7 11.3 25 18600 1.4 3.8 25600 2.0 3.7 25 34400 0.9 32.8 42800 1.7 24.9 30 22300 1.7 3.9 30200 2.3 3.8 30 34200 0.9 31.5 42400 1.8 23.6 40 27400 1.9 4.1 35500 2.6 4.0 40 33600 1.0 30.3 41300 1.8 22.4 50 32100 2.2 4.2 41400 3.0 4.1 50 32800 1.2 29.1 40000 2.4 16.6 60 80o 35800 2.4 4.4 50700 3.5 4.3 60 80o 31700 1.2 26.5 38000 2.5 15.1 70 42600 2.7 4.6 55800 3.7 4.5 70 30600 1.3 23.2 37600 2.4 16.0 80 45600 2.9 4.6 61800 4.1 4.5 80 29700 1.5 19.9 40400 2.5 15.9 90 49800 3.0 4.9 65800 4.1 4.7 90 27200 1.7 16.2 42200 3.0 14.3 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Dual Capacity RTVE 51 Data SheetElectrical Specification Mechanical Specifications Compressor (x2) Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Min. Air Coil Symbol RLA LRA FLA* HP* FLA HP Ampac. Max. Fuse/ Breaker Square Rows Tube Fins/ 208/230-1-60 1 26 118 4.3 .75 2.2 0.3 36.8 50 Feet Deep O.D. Inch 5 0.375 12Blower Performance Water Coil Type Working Press Static 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure Canister 600 psig CFM 1600 1550 1400 1370 1320 1260 1225 Blower Size Comp. Type 10 x 10 ScrollARI 13256-1 FULL LOAD Performance Data Rated at 1500 CFM and 11.0 GPM Net WEIGHT Shipping WeightPART LOAD Performance Data Rated at 1100CFM and 11.0 GPM 340 360GWHP 50F EWT HEATING 60F EWT COOLING
Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 248,000 58,600 23.0 18.0 37,400 51,200 4.0 4.3GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F COOLING Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 239,200 50,400 16.5 12.0 31,300 46,600 3.3 2.9Capacity Data All performance at 1150 CFM 1st stage; 1600 CFM 2nd stage and 11.0 GPMHEATING COOLINGEntering Total Power Total Power Entering Total Power Total Power Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity input EER Capacity input EER COP COP Temp Temp. T Temp (oF) (Bt H) (BtuH) (kW) (Bt H) (BtuH) (kW) Temp Temp. T Temp (oF) (BtuH) (kW) St Stage 1 (BtuH) (kW) Stage 2 St (oF) Stage 1 Stage 1 Stage 2 Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2 25 25600 1.9 4.0 36400 2.8 3.8 25 27500 1.0 27.4 34200 1.8 20.8 30 28800 2.1 4.1 39800 3.0 3.9 30 27400 1.0 26.3 33900 1.9 19.7 40 32300 2.2 4.3 44900 3.2 4.1 40 26800 1.1 25.3 33000 1.9 18.7 50 33200 2.2 4.4 46800 3.3 4.2 50 26200 1.1 24.3 32000 2.6 13.8 60 60o 37200 2.4 4.6 52100 3.5 4.4 60 60o 25300 1.1 22.1 30400 2.7 12.6 70 41900 2.6 4.8 57000 3.6 4.6 70 24500 1.3 19.3 30100 2.5 13.3 80 48500 3.0 4.8 65900 4.2 4.6 80 23700 1.4 16.5 32300 2.7 13.2 90 50500 2.9 5.1 68700 4.2 4.8 90 21800 1.6 13.4 33700 3.1 11.8 25 25100 1.9 3.9 35600 2.8 3.7 25 33900 1.1 31.9 42200 1.9 19.6 30 28300 2.1 4.0 39000 3.0 3.8 30 33800 1.0 32.8 41900 2.0 18.5 40 31700 2.2 4.2 44000 3.3 3.9 40 33100 1.0 32.1 40800 2.1 17.6 50 32600 2.2 4.3 45900 3.4 4.0 50 32400 1.1 28.9 39500 2.7 13.0 60 70 36500 2.4 4.5 51000 3.6 4.2 60 70 31300 1.2 26.3 37500 2.9 11.8 70 41100 2.6 4.7 55800 3.7 4.4 70 30200 1.3 23.0 37200 2.7 12.5 80 47500 3.0 4.7 64600 4.4 4.3 80 29300 1.5 19.7 39900 2.9 12.5 90 49500 2.9 4.9 67300 4.2 4.7 90 26900 1.7 16.0 41600 3.4 11.1 25 23300 1.8 3.8 33100 2.7 3.6 25 43000 0.9 32.6 53500 2.2 24.8 30 26300 2.0 3.9 36300 2.9 3.7 30 42800 0.9 31.3 53000 2.3 23.5 40 29500 2.1 4.1 41000 3.1 3.9 40 42000 1.0 30.1 51600 2.3 22.3 50 30300 2.1 4.2 42700 3.1 4.0 50 41000 1.2 28.9 50000 3.0 16.5 60 80o 33900 2.2 4.4 47500 3.3 4.2 60 80o 39600 1.5 26.3 47500 3.2 15.0 70 38200 2.4 4.6 51900 3.5 4.4 70 38300 1.7 23.0 47000 3.0 15.9 80 44200 2.8 4.6 60100 4.0 4.4 80 37100 1.9 19.7 50500 3.2 15.8 90 46000 2.8 4.9 62600 4.0 4.6 90 34000 2.1 16.0 52700 3.7 14.1 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Single Compressor Dual Capacity RTVE 60 Data SheetElectrical Specification Mechanical Specifications Compressor (x2) Blower Loop Pump Without Pumps Refrigerant: R-410A Voltage Elect. Min. Air Coil Symbol RLA LRA FLA* HP* FLA HP Ampac. Max. Fuse/ Breaker Square Rows Tube Fins/ 208/230-1-60 1 32.1 148 5 .75 2.2 0.3 45.1 70 Feet Deep O.D. Inch 3.88 5 0.375 12Blower Performance Water Coil Static Type Working Press 0.10 0.20 0.25 0.30 0.35 0.40 0.50Pressure Canister 600 psig CFM 1760 1700 1540 1500 1450 1386 1350 Blower Size Comp. Type 10 x 10 ScrollARI 13256-1 FULL LOAD Performance Data Rated at 1950 CFM and 13.0 GPM Net WEIGHT Shipping WeightPART LOAD Performance Data Rated at 1350 CFM and 13.0 GPM 355 380GWHP 50F EWT HEATING 60F EWT COOLING
Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 254,700 67,200 21.1 16.7 59,600 67,900 3.6 4.2GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F CO Cooling EER Heating COPStage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 226,800 60,300 17.7 9.3 38,600 52,200 3.4 3.3Capacity Data All performance at 1350 CFM 1st stage; 1900 CFM 2nd stage and 13.0 GPMHEATING COOLINGEntering Total Power Total Power Entering Total Power Total Power Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity Input EER Capacity input EER COP COP Temp. Temp (oF) (BtuH) (kW) (BtuH) (kW) Temp. Temp (oF) (BtuH) (kW) stage 1 (BtuH) (kW) Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2 25 30770 2.3 4.0 43600 3.3 3.9 25 27500 1.0 27.4 34200 1.8 20.8 30 34600 2.5 4.1 47700 3.5 4.0 30 27400 1.0 26.3 33900 1.9 19.7 40 38800 2.6 4.3 53900 3.8 4.2 40 26800 1.1 25.3 33000 1.9 18.7 50 39800 2.7 4.4 56200 3.9 4.3 50 26200 1.1 24.3 32000 2.6 13.8 60 60o 44600 2.8 4.6 62500 4.1 4.5 60 60o 25300 1.1 22.1 30400 2.7 12.6 70 50300 3.1 4.8 68400 4.3 4.7 70 24500 1.3 19.3 30100 2.5 13.3 80 58100 3.5 4.8 79100 5.0 4.7 80 23700 1.4 16.5 32300 2.7 13.2 90 60600 3.5 5.1 82400 4.9 4.9 90 26100 1.9 13.4 40500 3.8 11.8 25 30100 2.3 3.9 42800 3.3 3.8 25 33900 1.1 31.9 42200 1.9 19.6 30 33900 2.5 4.0 46800 3.6 3.9 30 33800 1.0 32.8 41900 2.0 18.5 40 38000 2.7 4.2 52900 3.8 4.0 40 33100 1.0 32.1 40800 2.1 17.6 50 39000 2.7 4.3 55100 3.9 4.1 50 32400 1.1 28.9 39500 2.7 13.0 60 70 43700 2.9 4.5 61200 4.1 4.3 60 70 31300 1.2 26.3 37500 2.9 11.8 68 49300 3.1 4.7 67000 4.3 4.5 70 30200 1.3 23.0 37200 2.7 12.5 80 57000 3.6 4.7 77500 5.0 4.5 80 29300 1.5 19.7 39900 2.9 12.5 90 59400 3.5 4.9 80800 4.9 4.8 90 32200 2.0 16.0 50000 4.0 11.1 25 28000 2.1 3.8 39800 3.1 3.7 25 43000 0.9 32.6 53500 2.2 24.8 30 31500 2.3 3.9 43500 3.3 3.8 30 42800 0.9 31.3 53000 2.3 23.5 40 35400 2.5 4.1 49200 3.6 4.0 40 42000 1.0 30.1 51600 2.3 22.3 50 36300 2.5 4.2 51200 3.7 4.1 50 41000 1.2 28.9 50000 3.0 16.5 60 80o 40700 2.7 4.4 56900 3.9 4.3 60 80o 39600 1.5 26.3 47500 3.2 15.0 70 45800 2.9 4.6 62300 4.1 4.5 70 38300 1.7 23.0 47000 3.0 15.9 80 53000 3.4 4.6 72100 4.7 4.5 80 37100 1.9 19.7 50500 3.2 15.8 90 55200 3.3 4.9 75100 4.6 4.7 90 40800 2.6 16.0 63200 4.5 14.1 NORTHERN HEAT PUMP 3-201 South Railway Ave
Winkler, Manitoba R6W 1J9, CANADANorthern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954 Water to water heat pumps. XTERRA SERIES Stainless steel cabinet Insulated to reduce condensation Compressor is high efficiency scroll Safety devices to prevent compressor damageAQUA2 R410ARAWE 368 gpm loop 5 gpm hyd. 8 gpm loop 5 gpm hyd
HEATING COOLING LOOP HYD CAP LOOP HYD HR EWT LWT MBTU/hr KW COP EWT LWT MBTU/hr KW EER 70.0 25.7 1.7 4.4 35.0 31.5 1.6 19.7 85.0 25.6 1.8 4.2 40.0 33.4 1.6 20.8 100.0 25.5 2.1 3.6 50 45.0 35.3 1.6 21.8 25 110.0 25.4 2.3 3.3 50.0 36.6 1.6 22.3 115.0 25.3 2.5 3.0 55.0 37.9 1.7 22.7 120.0 25.2 3.1 2.4 35.0 32.1 1.9 17.1 70.0 28.3 1.6 5.1 40.0 34.1 1.9 18.2 85.0 27.6 1.4 4.7 60 45.0 36.2 1.9 19.3 100.0 27.3 2.0 4.0 50.0 37.7 1.9 19.8 30 110.0 27.1 2.2 3.6 55.0 39.1 1.9 20.3 115.0 27.0 2.4 3.3 35.0 32.8 2.3 14.4 120.0 26.6 3.0 2.6 40.0 34.9 2.2 15.6 70.0 31.0 1.6 5.7 70 45.0 37.1 2.2 16.8 85.0 29.5 1.7 5.2 50.0 38.7 2.2 17.3 100.0 29.1 2.0 4.4 55.0 40.4 2.3 17.8 35 110.0 28.7 2.1 4.0 Data subject to change without notice 115.0 28.7 2.3 3.6 120.0 27.9 2.8 2.9 70.0 32.9 1.5 6.4 85.0 31.4 1.6 5.6 100.0 31.0 1.9 4.7 40 110.0 30.5 2.1 4.3 115.0 30.5 2.3 3.9 120.0 29.7 2.8 3.2 70.0 36.8 1.5 7.0 85.0 37.7 1.8 6.1 100.0 37.1 2.1 5.1 50 110.0 36.5 2.3 4.7 115.0 35.9 2.5 4.2 120.0 34.8 3.0 3.4R d outsideRated id the h scope off ARIAQUA2 R410ARAWE 5011 gpm loop 8 gpm hyd. 11 gpm loop 8 gpm hyd
HEATING COOLING LOOP HYD CAP LOOP HYD CAP EWT LWT MBTU/hr KW COP EWT LWT MBTU/hr KW EER 70.0 38.7 2.6 4.4 35.0 39.6 2.1 19.3 85.0 38.8 2.9 3.9 40.0 42.3 2.1 20.4 100.0 38.7 3.4 3.3 50 45.0 44.9 2.1 21.5 25 110.0 38.5 4.0 2.9 50.0 46.8 2.1 21.9 115.0 38.4 4.2 2.7 55.0 48.6 2.2 22.3 120.0 37.9 4.6 2.4 35.0 39.3 2.4 16.7 70.0 40.8 2.3 5.1 40.0 42.3 2.4 17.9 85.0 40.7 2.7 4.4 60 45.0 45.2 2.4 19.0 100.0 40.6 3.2 3.7 50.0 47.2 2.4 19.5 30 110.0 40.4 3.8 3.2 55.0 49.3 2.5 19.9 115.0 40.3 3.9 3.0 35.0 39.1 2.8 14.1 120.0 39.8 4.5 2.6 40.0 42.3 2.8 15.3 70.0 47.0 2.5 5.6 70 45.0 45.4 2.8 16.5 85.0 44.9 2.7 4.9 50.0 47.7 2.8 17.0 100.0 44.3 3.2 4.1 55.0 50.0 2.9 17.5 35 110.0 44.0 3.5 3.7 Data subject to change without notice 115.0 43.7 3.8 3.4 120.0 42.3 4.4 2.9 70.0 50.0 2.4 6.2 85.0 47.7 2.6 5.4 100.0 47.1 3.1 4.5 40 110.0 46.8 3.4 4.1 115.0 46.4 3.7 3.7 120.0 45.0 4.3 3.1 70.0 56.4 2.4 6.8 85.0 57.3 2.8 5.9 100.0 56.4 3.4 4.9 50 110.0 55.5 3.7 4.5 115.0 54.6 4.0 4.0 120.0 53.0 4.7 3.3Rated outside the scope of ARI
NORTHERN HEAT PUMP INC. Specification Manual Ground Source Heat Pumps XTERRA SERIES FORCAIR RAVE/ RAHE 36 THRU 70 FORCAIR2 RTVE/ RTHE 30 THRU 60 AQUA2 …
High-tech, efficient, simple, compact, beautifully engineered in a stainless steel shell - are a few of the reasons you should choose Northern Heat Pump for your heating and cooling needs. Click here for more information. Here are two diagrams explaining the process of heating and cooling using Geothermal Heat Pumps
HVAC Services in Upstate NY! Northern Heating and Air in Queensbury NY is ready to take care of all your heating and air conditioning needs, including installation, repair, replacement, and maintenance. Our HVAC services include air conditioners, furnaces, heat pumps, thermostats and boilers for residential and commercial services.
Northern Heating and Air is proud to offer true 24-hour emergency service, so someone is always on call to help, no matter what time of day – or night – you may need us.