NORTHERN HEAT PUMP INC

Specification Manual
Ground Source Heat Pumps
XTERRA SERIES
FORCAIR RAVE/ RAHE 36 THRU 70
FORCAIR2 RTVE/ RTHE 30 THRU 60
AQUA2 RAWE/CDWE 36 THRU 140
SOURC3 RMVE/ RMHE 36 THRU 70
Rev 9
Mar-27-09
DESCRIPTIONS
RESIDENTIAL MODEL # DESCRIPTION
RA VE 502 - C 1 3 1
UNIT DESIGNATION POWER SUPPLY
R=RESIDENTIAL 1=208/230V 1Ph
2=208/230V 3Ph
3=575V 3Ph
4=460/480V 3PH
UNIT TYPE 5=220/240V 1PH 50HZ
A=STANDARD 6=380V 3PH 50HZ
M=MULTI
D=DUAL COMPRESSOR
S=SPECIAL
W=HEAT ONLY BLOWER TYPE
T=TWO SPEED 1=None
P=MINI 2=Standard PSC 3 Speed Blower
3=ECM Blower
UNIT STYLE
W=HYDRONIC
V=VERTICAL
D=DOWNFLOW CONFIGURATION
H=HORIZONTAL 1=LEFT SIDE RETURN (STD)
S=SPLIT 2=RIGHT SIDE RETURN
3=NONE
REFRIGERANT TYPE
E=R410A REFRIGERANT
F=R22 REFRIGERANT
HEAT EXCHANGER
NORMAL SIZE C=COPPER
X 1000 BTU/H F=S.S. FLATPLATE
H=CUPRO HYDRONIC LOOP
N=CUPRO NICKEL
DESUPERHEATER OPTION
1=NONE
2=PARTIAL DESUPERHEATER
3=FULL TIME
SERIAL # DESCRIPTION
XL 08 01 A 1000 A
BILL OF MFG MFG LOCATION
A=SOUTH RAILWAY PLANT
YEAR OF MFG
SEQUENTIAL NUMBER
MONTH OF MFG
FUTURE USE
A=LINE NUMBER
DESCRIPTIONS
COMMERCIAL MODEL # DESCRIPTION
CD WE 114 2 - C 1 1
UNIT DESIGNATION
C=COMMERCIAL POWER SUPPLY
1=208/230V 1Ph
2=208/230V 3Ph
3=575V 3Ph
4=460/480V 3PH
UNIT TYPE 5=220/240V 1PH 50HZ
A=STANDARD 6=380V 3PH 50HZ
M=MULTI
D=DUAL COMPRESSOR
S=SPECIAL BLOWER TYPE
W=HEAT ONLY 1=None
T=TWO SPEED 2=Standard PSC 3 Speed Blower
P=MINI 3=ECM Blower
UNIT STYLE
W=HYDRONIC
V=VERTICAL
D=DOWNFLOW HEAT EXCHANGER
H=HORIZONTAL C=COPPER
S=SPLIT F=S.S. FLATPLATE
H=CUPRO HYDRONIC LOOP
REFRIGERANT TYPE N=CUPRO NICKEL
E=R410A REFRIGERANT
F=R22 REFRIGERANT
NORMAL SIZE DESUPERHEATER OPTION
X 1000 BTU/H 1=NONE
2=PARTIAL DESUPERHEATER
3=FULL TIME
SERIAL # DESCRIPTION
XL 08 01 A 1000 A
BILL OF MFG MFG LOCATION
A=SOUTH RAILWAY PLANT
YEAR OF MFG
SEQUENTIAL NUMBER
MONTH OF MFG
FUTURE USE
A=LINE NUMBER
Single Compressor Single Capacity
RAVE 36
Data Sheet
Electrical Specification Mechanical Specifications
Compressor Blower Loop Pump Without pumps Refrigerant: R-410A
Voltage Elect. Total Min. Max. Fuse/ Air Coil
Symbol RLA LRA FLA HP FLA HP FLA Ampac Breaker Square Rows Tube Fins/
208/230-1-60 1 20 112 4.3 .5 2.2 1/3 24.3 29.3 40 Feet Deep O.D. Inch
575-3-60 3 5.7 34.1 4.3 .5 - - 10 11.4 15 2.78 5 0.375 12
*HACR - type breaker per NEC Water Coil
Type Working Press
Canister 600 psig
Blower Size Comp. Type
9x9 Scroll
Blower Performance Net Weight Shipping Weight
Static 305 355
0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure
CFM 1200 1100 1060 1020 975 950 885
ISO 13256-1 Performance Data Rated at 1100 CFM and 7.0 GPM
Ground Water Ground Loop
Cooling Heating Cooling Heating
Capacity EER Capacity COP Capacity EER Capacity COP
35,300 19.9 34,700 4.3 46,600 13.3 31,100 3.0
Capacity Data All performance at 1100 CFM and 7.0 GPM
HEATING COOLING
Entering Total Entering Total
Power
Fluid Entering Air Capacity Fluid Entering Air Capacity Power
input COP EER
Temp

T Temp (oF) (BtuH)
(B H) Temp

T Temp (oF) H) iinputt (kW)
(BtuH)
(B
(kW)
(oF) Stage 1 (oF) Stage 1
25 32000 2.1 4.4 25 27900 1.8 22.7
30 33400 2.1 4.6 30 27100 1.8 21.8
40 34000 2.2 4.5 40 26900 1.8 21.0
50 37900 2.2 5.0 50 26200 1.8 20.2
60 60o 41600 2.4 5.1 60 60o 25300 2.0 17.6
70 46100 2.5 5.4 70 24800 2.2 14.3
80 47300 2.7 5.2 80 25900 2.4 12.6
90 48100 2.8 5.1 90 27000 2.7 9.2
25 31400 2.3 2.7 25 34400 1.9 21.3
30 32700 2.3 2.8 30 33500 1.9 20.5
40 33400 2.4 3.2 40 33200 2.0 19.8
50 37100 2.4 3.6 50 32300 2.0 19.0
60 68o 40800 2.6 4.3 60 68o 31200 2.2 16.6
70 45200 2.7 4.4 70 30600 2.3 13.4
80 46400 2.9 4.3 80 32000 2.6 11.9
90 47200 3.0 5.2 90 33300 2.9 8.7
25 29200 2.4 3.6 25 43600 2.1 27
30 30400 2.4 3.8 30 42400 2.1 26
40 31000 2.5 3.7 40 42000 2.2 25
50 34500 2.5 4.1 50 40900 2.2 24
60 80o 37900 2.7 4.2 60 80o 39500 2.4 21
70 42000 2.8 4.4 70 38700 2.6 17
80 43200 3.0 4.3 80 40500 2.9 15
90 43900 3.1 4.2 90 41200 3.2 11
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Single Capacity
RAVE 50
Data Sheet
Electrical Specification Mechanical Specifications
Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Total Min. Max. Fuse/ Air Coil
Symbol RLA LRA FLA* HP* FLA HP FLA Ampac. Breaker Square Rows Tube Fins/
208/230-1-60 1 30 145 4.3 .75 2.2 0.3 34.3 41.8 60 Feet Deep O.D. Inch
3.88 5 0.375 12
Water Coil
Type Working Press
Canister 600 psig
Blower Size Comp. Type
Blower Performance 10 x 10 Scroll
Static Net WEIGHT Shipping Weight
0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure 320 340
CFM 1640 1550 1495 1440 1390 1360 1290
ISO 13256-1 Performance Data Rated at 1550 CFM and 13.0GPM
Ground Water Ground Loop
Cooling Heating Cooling Heating
Capacity EER Capacity COP Capacity EER Capacity COP
48,900 20.2 45,600 4.1 47,000 11.5 36,000 2.9
Capacity Data All performance rated at 1550 CFM and 10.0 GPM
HEATING COOLING
Entering Total Entering Total
Power
Fluid Entering Air Capacity Fluid Entering Air Capacity Power
input COP EER
Temp. Temp (oF) (BtuH) Temp. Temp (oF) (BtuH) input (kW)
(kW)
(oF) Stage 1 (oF) Stage 1
25 43500 2.6 4.9 25 36400 1.6 23.4
30 45400 2.8 4.7 30 35400 1.6 22.6
40 46300 3.0 4.5 40 35100 1.7 21.0
50 51600 3.2 4.7 50 34200 1.9 18.3
60 60o 56600 3.3 5.0 60 60o 33000 2.0 16.5
70 62700 3.4 5.4 70 32400 2.4 13.5
80 64400 3.4 5.5 80 33800 3.0 11.1
90 65500 3.6 5.3 90 35300 3.9 9.1
25 42700 4.2 3.0 25 44900 2.0 22.0
30 44500 4.1 3.2 30 43700 2.1 21.2
40 45500 3.4 3.9 40 43300 2.2 19.7
50 50500 3.4 4.3 50 42200 2.4 17.2
60 68o 55500 3.6 4.5 60 68o 40700 2.6 15.5
68 61500 3.9 4.6 68 40000 3.2 12.7
80 63200 3.8 4.9 80 41800 4.0 10.5
90 64200 3.9 4.8 90 43500 5.1 8.6
25 39700 2.9 4.0 25 56900 2.0 27.8
30 41400 3.1 3.9 30 55400 2.1 26.9
40 42200 3.3 3.7 40 54800 2.2 25.0
50 47000 3.6 3.9 50 53400 2.5 21.8
60 80o 51600 3.7 4.1 60 80o 51600 2.6 19.6
70 57200 3.8 4.4 70 50500 3.2 16.0
80 58800 3.8 4.5 80 52900 4.0 13.2
90 59800 4.0 4.4 90 53800 5.0 10.8
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Single Capacity RAVE 57
Data Sheet
Electrical Specification Mechanical Specifications
Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Total Min. Max. Fuse/ Air Coil
Symbol RLA LRA FLA HP FLA HP FLA Ampac Breaker* Square Rows Tube Fins/
208/230-1-60 1 33.6 158 5.0 0.75 2.2 1/6(x2) 38.6 47.0 70 Feet Deep O.D. Inch
575-3-60 3 8.6 54 2.2 0.75 - - 10.8 13.6 15 3.88 5 0.375 12
*HACR - type breaker per NEC Water Coil
Type Working Press
Canister 600 psig
Blower Size Comp. Type
10 x 10 Scroll
Blower Performance Net Weight Shipping Weight
Static 340 365
0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure
CFM 1800 1700 1640 1580 1525 1490 1410
ISO 13256-1 Performance Data Rated at 1700 CFM and 14.0GPM
Ground Water Ground Loop
Cooling Heating Cooling Heating
Capacity EER Capacity COP Capacity EER Capacity COP
53,600 20.4 51,300 4.2 62,400 11.6 44,700 3.2
Capacity Data All performance rated at 1700 CFM and 13.0 GPM
HEATING COOLING 57000
Entering
E t i Total
T t l Entering
E t i T t l
Total
Power Power
Fluid Entering Air Capacity Fluid Entering Air Capacity
input COP input EER
Temp. Temp (oF) (BtuH) Temp. Temp (oF) (BtuH)
(kW) (kW)
(oF) Stage 1 (oF) Stage 1
25 49600 3.2 4.5 25 43300 1.8 23.9
30 51800 3.5 4.4 30 42100 1.8 23.0
40 52700 3.7 4.2 40 41700 2.0 21.4
50 58800 4.0 4.4 50 40700 2.2 18.7
60 60o 64500 4.1 4.6 60 60o 39300 2.3 16.8
70 71500 4.2 5.0 70 38500 2.8 13.7
80 73400 4.2 5.1 80 40200 3.5 11.4
90 74600 4.4 4.9 90 41900 4.5 9.3
25 48700 5.1 2.8 25 53400 2.4 22.5
30 50700 5.0 3.0 30 52000 2.4 21.7
40 51800 4.2 3.6 40 51500 2.6 20.1
50 57600 4.2 4.0 50 50100 2.9 17.6
60 68o 63300 4.4 4.2 60 68o 48400 3.1 15.8
68 70100 4.8 4.3 68 47500 3.7 12.9
80 72000 4.6 4.6 80 49700 4.6 10.7
90 73200 4.8 4.5 90 51700 5.9 8.7
25 45300 3.6 3.7 25 67700 2.4 28.4
30 47200 3.8 3.6 30 65700 2.4 27.4
40 48100 4.1 3.4 40 65200 2.6 25.5
50 53500 4.4 3.6 50 63500 2.9 22.2
60 80o 58800 4.5 3.8 60 80o 61300 3.1 20.0
70 65200 4.7 4.1 70 6010 3.7 16.4
80 67000 4.7 4.2 80 62800 4.6 13.5
90 68100 4.9 4.0 90 63900 5.8 11.1
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Single Capacity
RAVE 70
Data Sheet
Electrical Specification Mechanical Specifications
Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Min Max. Fuse/ Air Coil
Symbol RLA LRA FLA* HP* FLA HP FLA Circuit Breaker Square Rows Tube Fins/
208/230-1-60 1 35.7 148 5 .75 2.2 0.3 40.7 49.6 70 Feet Deep O.D. Inch
3.88 5 0.375 12
Water Coil
Type Working Press
Brazed Plate 600 psig
Blower Performance Blower Size Comp. Type
Static 10 x 10 Scroll
0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure Net WEIGHT Shipping Weight
CFM 2020 1900 1840 1770 1710 1670 1580 355 380
ISO 13256-1 Performance Data Rated at 1900 CFM and 15.0GPM
Ground Water Ground Loop
Cooling Heating Cooling Heating
Capacity EER Capacity COP Capacity EER Capacity COP
73,300 20.6 63,900 4.1 72,400 10.0 57,400 3.0
Capacity Data All performance rated at 1900 CFM and 15.0 GPM
HEATING COOLING
Entering Total Entering
Power Total
Fluid Entering Air p
Capacityy Fluid Entering Air Power
input COP Capacity EER
Temp. Temp (oF) (BtuH) Temp. Temp (oF) input (kW)
(kW) (BtuH)
(oF) Stage 1 (oF)
25 60395 3.6 4.9 25 53200 2.2 24.1
30 62900 3.9 4.7 30 51600 2.2 23.3
40 64100 4.2 4.5 40 51300 2.4 21.6
50 71500 4.5 4.7 50 49900 2.6 18.9
60 60o 78500 4.6 5.0 60 60o 48200 2.8 17.0
70 87000 4.8 5.4 70 47300 3.4 13.9
80 89200 4.7 5.5 80 49300 4.3 11.5
90 90700 5.0 5.3 90 51500 5.5 9.4
25 59200 5.8 3.0 25 65600 2.9 22.7
30 61700 5.6 3.2 30 63800 2.9 21.9
40 63000 4.7 3.9 40 63300 3.1 20.3
50 70000 4.8 4.3 50 61500 3.5 17.8
60 68o 77000 5.0 4.5 60 70o 59500 3.7 16.0
70 85300 5.4 4.6 68 58300 4.5 13.1
80 87500 5.2 4.9 80 61000 5.6 10.8
90 89000 5.4 4.8 90 63500 7.2 8.8
25 55100 4.0 4.0 25 83100 2.9 28.7
30 57300 4.3 3.9 30 80800 2.9 27.7
40 58500 4.6 3.7 40 80000 3.1 25.7
50 65100 5.0 3.9 50 77900 3.5 22.5
60 80o 71500 5.1 4.1 60 80o 75300 3.7 20.2
70 79200 5.3 4.4 70 73700 4.5 16.5
80 81500 5.3 4.5 80 77200 5.6 13.7
90 82800 5.6 4.4 90 78300 7.0 11.2
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Dual Capacity RTVE 30
Data Sheet
Electrical Specification Mechanical Specifications
Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Total Min. Max. Fuse/ Air Coil
Symbol RLA LRA FLA* HP* FLA HP FLA Ampac. Breaker Square Rows Tube Fins/
208/230-1-60 1 19 82 4.3 .75 2.2 1/3 23.3 28.1 40 Feet Deep O.D. Inch
3.88 5 0.375 12
Blower Performance Water Coil
Type Working Press
Static 0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure Canister 600 psig
CFM 1020 980 898 865 832 796 775 Blower Size Comp. Type
10 x 10 Scroll
ARI 13256-1 FULL LOAD Performance Data Rated at 1000 CFM and 7.0 GPM Net WEIGHT Shipping Weight
PART LOAD Performance Data Rated at 700 CFM and 7.0 GPM 305 355
GWHP 50F EWT HEATING 60F EWT COOLING

Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
28,230 31,400 22.9 15.45 21,880 31,200 3.9 3.9
GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F COOLING
Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
26,700 34,100 23.0 15.5 16,800 24,000 3.3 3.2
Capacity Data All performance at 700 CFM 1st stage; 980 CFM 2nd stage and 7.0 GPM
HEATING COOLING
Entering Total Power Total Power Entering Total Power Total Power
Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity input EER Capacity input EER
COP COP
Temp. Temp (oF) (BtuH) (kW) (BtuH) (kW) Temp. Temp (oF) (BtuH) (kW) Stage 1 (BtuH) (kW) Stage 2
o o
( F) Stage 1 Stage 1 Stage 2 Stage 2 ( F) Stage 1 Stage 1 Stage 2 Stage 2
25 17200 1.3
13 4.0
40 22700 1.7
17 3.9
39 25 28400 1.0
10 27.6
27 6 35800 1.9
19 20.9
20 9
30 19000 1.4 4.1 25300 1.9 4.0 30 28100 1.1 26.5 35600 2.0 19.8
40 22000 1.5 4.3 29400 2.1 4.2 40 27700 1.1 25.5 33900 2.0 18.8
50 o 26100 1.7 4.4 34400 2.4 4.3 50 o 24300 1.0 24.4 29800 2.4 13.9
60 60 29100 1.9 4.6 38400 2.5 4.5 60 60 21400 1.0 22.3 25500 2.2 12.7
70 33300 2.0 4.8 44000 2.8 4.7 70 20900 1.1 19.5 22400 1.8 13.4
80 34600 2.1 4.8 45600 2.9 4.7 80 18500 1.1 16.7 20800 1.7 13.4
90 35000 2.0 5.1 46200 2.7 4.9 90 18000 1.3 13.6 20200 1.9 12.0
25 16800 1.3 3.9 19900 1.5 3.8 25 35000 1.1 33.1 44200 2.0 19.7
30 18800 1.4 4.0 21300 1.6 3.9 30 34700 1.0 33.1 44000 2.1 18.7
40 21900 1.5 4.2 25000 1.8 4.0 40 34200 1.1 32.3 41800 2.1 17.7
50 25600 1.8 4.3 28100 2.0 4.1 50 29900 1.0 29.1 36800 2.5 13.1
60
70 28600 1.9 4.5 35700 2.4 4.3 60
70 26400 1.0 26.5 31500 2.4 11.9
70 32700 2.1 4.7 39300 2.6 4.5 70 25800 1.1 23.2 27700 2.0 12.6
80 33900 2.1 4.7 43600 2.8 4.5 80 22900 1.2 19.9 25600 1.8 12.6
90 34300 2.0 4.9 46400 2.8 4.8 90 22200 1.4 16.2 24900 2.0 11.3
25 15600 1.2 3.8 16800 1.3 3.7 25 44300 0.9 32.8 56000 2.2 24.9
30 17500 1.3 3.9 19800 1.5 3.8 30 43900 0.9 31.5 55700 2.4 23.6
40 20300 1.4 4.1 23300 1.7 4.0 40 43300 1.0 30.3 52900 2.4 22.4
50 23800 1.7 4.2 27100 1.9 4.1 50 37900 1.2 29.1 46600 2.8 16.6
60 80o 26600 1.8 4.4 33200 2.3 4.3 60 80o 33400 1.3 26.5 39800 2.6 15.1
70 30400 1.9 4.6 36600 2.4 4.5 70 32700 1.4 23.2 35000 2.2 16.0
80 31500 2.0 4.6 40500 2.7 4.5 80 29000 1.5 19.9 32500 2.0 15.9
90 31900 1.9 4.9 43100 2.7 4.7 90 28100 1.7 16.2 31500 2.2 14.3
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Dual Capacity RTVE 40
Data Sheet
Electrical Specification Mechanical Specifications
Compressor Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Total Min. Max. Fuse/ Air Coil
Symbol RLA LRA FLA* HP* FLA HP FLA Ampac. Breaker Square Rows Tube Fins/
208/230-1-60 1 24 96 4.3 .75 2.2 1/3 34.3 34.3 50 Feet Deep O.D. Inch
3.88 5 0.375 12
Blower Performance Water Coil
Type Working Press
Static 0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure Canister 600 psig
CFM 1250 1200 1100 1060 1020 975 950 Blower Size Comp. Type
10 x 10 Scroll
ARI 13256-1 FULL LOAD Performance Data Rated at 1300 CFM and 9.0 GPM Net WEIGHT Shipping Weight
PART LOAD Performance Data Rated at 1100 CFM and 9.0 GPM 325 375
GWHP 50F EWT HEATING 60F EWT COOLING

Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
36,550 45,920 23.4 19.0 28,900 43,770 3.8 3.8
GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F COOLING
Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
37,500 46,200 20.6 14.7 28,000 34,600 3.6 3.2
Capacity Data All performance at 750 CFM 1st stage; 1200 CFM 2nd stage and 9.0 GPM
HEATING COOLING
Entering Total Power Total Power Entering Total Power Total Power
Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity input EER Capacity input EER
COP COP
Temp. Temp (oF) (BtuH) (kW) (BtuH) (kW) Temp. Temp (oF) (BtuH) (kW) Stage 1 (BtuH) (kW) Stage 2
(oF) Stage 1 Stage 1 Stage 2 Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2
25 20400 1.5 4.0 28100 2.1 3.9 25 22000 0.8 27.6 27400 1.4 20.9
30 24500 1.7 4.1 33200 2.4 4.0 30 22000 0.8 26.5 27100 1.5 19.8
40 30100 21
2.1 43
4.3 39000 27
2.7 42
4.2 40 21500 08
0.8 25 5
25.5 26400 15
1.5 18 8
18.8
50 35200 2.3 4.4 45400 3.1 4.3 50 21000 0.9 24.4 25600 2.0 13.9
60 60o 39300 2.5 4.6 55600 3.7 4.5 60 60o 20300 0.9 22.3 24300 2.1 12.7
70 46700 2.9 4.8 61200 3.9 4.7 70 19600 1.0 19.5 24100 2.0 13.4
80 50000 3.1 4.8 67800 4.3 4.7 80 19000 1.1 16.7 25800 2.1 13.4
90 54600 3.1 5.1 72200 4.3 4.9 90 17400 1.3 13.6 27000 2.5 12.0
25 20000 1.5 3.9 27500 2.1 3.8 25 27100 0.8 32.9 33800 1.5 19.7
30 24000 1.8 4.0 32500 2.5 3.9 30 27000 0.8 33.0 33500 1.6 18.7
40 29500 2.1 4.2 38200 2.8 4.0 40 26500 0.8 32.1 32600 1.7 17.7
50 34500 2.4 4.3 44500 3.2 4.1 50 25900 0.9 28.9 31600 2.2 13.1
60 70 38500 2.5 4.5 54500 3.7 4.3 60 70 25000 1.0 26.3 30000 2.3 11.9
68 45800 2.9 4.7 60000 3.9 4.5 68 24200 1.1 23.0 29700 2.1 12.6
80 49000 3.1 4.7 66500 4.3 4.5 80 23400 1.2 19.7 31900 2.3 12.6
90 53500 3.2 4.9 70800 4.3 4.8 90 21500 1.3 16.1 33300 2.7 11.3
25 18600 1.4 3.8 25600 2.0 3.7 25 34400 0.9 32.8 42800 1.7 24.9
30 22300 1.7 3.9 30200 2.3 3.8 30 34200 0.9 31.5 42400 1.8 23.6
40 27400 1.9 4.1 35500 2.6 4.0 40 33600 1.0 30.3 41300 1.8 22.4
50 32100 2.2 4.2 41400 3.0 4.1 50 32800 1.2 29.1 40000 2.4 16.6
60 80o 35800 2.4 4.4 50700 3.5 4.3 60 80o 31700 1.2 26.5 38000 2.5 15.1
70 42600 2.7 4.6 55800 3.7 4.5 70 30600 1.3 23.2 37600 2.4 16.0
80 45600 2.9 4.6 61800 4.1 4.5 80 29700 1.5 19.9 40400 2.5 15.9
90 49800 3.0 4.9 65800 4.1 4.7 90 27200 1.7 16.2 42200 3.0 14.3
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Dual Capacity RTVE 51
Data Sheet
Electrical Specification Mechanical Specifications
Compressor (x2) Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Min. Air Coil
Symbol RLA LRA FLA* HP* FLA HP Ampac. Max. Fuse/ Breaker Square Rows Tube Fins/
208/230-1-60 1 26 118 4.3 .75 2.2 0.3 36.8 50 Feet Deep O.D. Inch
5 0.375 12
Blower Performance Water Coil
Type Working Press
Static 0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure Canister 600 psig
CFM 1600 1550 1400 1370 1320 1260 1225 Blower Size Comp. Type
10 x 10 Scroll
ARI 13256-1 FULL LOAD Performance Data Rated at 1500 CFM and 11.0 GPM Net WEIGHT Shipping Weight
PART LOAD Performance Data Rated at 1100CFM and 11.0 GPM 340 360
GWHP 50F EWT HEATING 60F EWT COOLING

Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
48,000 58,600 23.0 18.0 37,400 51,200 4.0 4.3
GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F COOLING
Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
39,200 50,400 16.5 12.0 31,300 46,600 3.3 2.9
Capacity Data All performance at 1150 CFM 1st stage; 1600 CFM 2nd stage and 11.0 GPM
HEATING COOLING
Entering Total Power Total Power Entering Total Power Total Power
Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity input EER Capacity input EER
COP COP
Temp
Temp. T
Temp (oF) (Bt H)
(BtuH) (kW) (Bt H)
(BtuH) (kW) Temp
Temp. T
Temp (oF) (BtuH) (kW) St
Stage 1 (BtuH) (kW) Stage 2
St
(oF) Stage 1 Stage 1 Stage 2 Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2
25 25600 1.9 4.0 36400 2.8 3.8 25 27500 1.0 27.4 34200 1.8 20.8
30 28800 2.1 4.1 39800 3.0 3.9 30 27400 1.0 26.3 33900 1.9 19.7
40 32300 2.2 4.3 44900 3.2 4.1 40 26800 1.1 25.3 33000 1.9 18.7
50 33200 2.2 4.4 46800 3.3 4.2 50 26200 1.1 24.3 32000 2.6 13.8
60 60o 37200 2.4 4.6 52100 3.5 4.4 60 60o 25300 1.1 22.1 30400 2.7 12.6
70 41900 2.6 4.8 57000 3.6 4.6 70 24500 1.3 19.3 30100 2.5 13.3
80 48500 3.0 4.8 65900 4.2 4.6 80 23700 1.4 16.5 32300 2.7 13.2
90 50500 2.9 5.1 68700 4.2 4.8 90 21800 1.6 13.4 33700 3.1 11.8
25 25100 1.9 3.9 35600 2.8 3.7 25 33900 1.1 31.9 42200 1.9 19.6
30 28300 2.1 4.0 39000 3.0 3.8 30 33800 1.0 32.8 41900 2.0 18.5
40 31700 2.2 4.2 44000 3.3 3.9 40 33100 1.0 32.1 40800 2.1 17.6
50 32600 2.2 4.3 45900 3.4 4.0 50 32400 1.1 28.9 39500 2.7 13.0
60 70 36500 2.4 4.5 51000 3.6 4.2 60 70 31300 1.2 26.3 37500 2.9 11.8
70 41100 2.6 4.7 55800 3.7 4.4 70 30200 1.3 23.0 37200 2.7 12.5
80 47500 3.0 4.7 64600 4.4 4.3 80 29300 1.5 19.7 39900 2.9 12.5
90 49500 2.9 4.9 67300 4.2 4.7 90 26900 1.7 16.0 41600 3.4 11.1
25 23300 1.8 3.8 33100 2.7 3.6 25 43000 0.9 32.6 53500 2.2 24.8
30 26300 2.0 3.9 36300 2.9 3.7 30 42800 0.9 31.3 53000 2.3 23.5
40 29500 2.1 4.1 41000 3.1 3.9 40 42000 1.0 30.1 51600 2.3 22.3
50 30300 2.1 4.2 42700 3.1 4.0 50 41000 1.2 28.9 50000 3.0 16.5
60 80o 33900 2.2 4.4 47500 3.3 4.2 60 80o 39600 1.5 26.3 47500 3.2 15.0
70 38200 2.4 4.6 51900 3.5 4.4 70 38300 1.7 23.0 47000 3.0 15.9
80 44200 2.8 4.6 60100 4.0 4.4 80 37100 1.9 19.7 50500 3.2 15.8
90 46000 2.8 4.9 62600 4.0 4.6 90 34000 2.1 16.0 52700 3.7 14.1
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Single Compressor Dual Capacity
RTVE 60
Data Sheet
Electrical Specification Mechanical Specifications
Compressor (x2) Blower Loop Pump Without Pumps Refrigerant: R-410A
Voltage Elect. Min. Air Coil
Symbol RLA LRA FLA* HP* FLA HP Ampac. Max. Fuse/ Breaker Square Rows Tube Fins/
208/230-1-60 1 32.1 148 5 .75 2.2 0.3 45.1 70 Feet Deep O.D. Inch
3.88 5 0.375 12
Blower Performance Water Coil
Static Type Working Press
0.10 0.20 0.25 0.30 0.35 0.40 0.50
Pressure Canister 600 psig
CFM 1760 1700 1540 1500 1450 1386 1350 Blower Size Comp. Type
10 x 10 Scroll
ARI 13256-1 FULL LOAD Performance Data Rated at 1950 CFM and 13.0 GPM Net WEIGHT Shipping Weight
PART LOAD Performance Data Rated at 1350 CFM and 13.0 GPM 355 380
GWHP 50F EWT HEATING 60F EWT COOLING

Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
54,700 67,200 21.1 16.7 59,600 67,900 3.6 4.2
GLHP 32F EWT HEATING 77F EWT COOLING. PART LOAD 41F HEATING 60F CO
Cooling EER Heating COP
Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2
26,800 60,300 17.7 9.3 38,600 52,200 3.4 3.3
Capacity Data All performance at 1350 CFM 1st stage; 1900 CFM 2nd stage and 13.0 GPM
HEATING COOLING
Entering Total Power Total Power Entering Total Power Total Power
Fluid Entering Air Capacity input Capacity input Fluid Entering Air Capacity Input EER Capacity input EER
COP COP
Temp. Temp (oF) (BtuH) (kW) (BtuH) (kW) Temp. Temp (oF) (BtuH) (kW) stage 1 (BtuH) (kW) Stage 2
(oF) Stage 1 Stage 1 Stage 2 Stage 2 (oF) Stage 1 Stage 1 Stage 2 Stage 2
25 30770 2.3 4.0 43600 3.3 3.9 25 27500 1.0 27.4 34200 1.8 20.8
30 34600 2.5 4.1 47700 3.5 4.0 30 27400 1.0 26.3 33900 1.9 19.7
40 38800 2.6 4.3 53900 3.8 4.2 40 26800 1.1 25.3 33000 1.9 18.7
50 39800 2.7 4.4 56200 3.9 4.3 50 26200 1.1 24.3 32000 2.6 13.8
60 60o 44600 2.8 4.6 62500 4.1 4.5 60 60o 25300 1.1 22.1 30400 2.7 12.6
70 50300 3.1 4.8 68400 4.3 4.7 70 24500 1.3 19.3 30100 2.5 13.3
80 58100 3.5 4.8 79100 5.0 4.7 80 23700 1.4 16.5 32300 2.7 13.2
90 60600 3.5 5.1 82400 4.9 4.9 90 26100 1.9 13.4 40500 3.8 11.8
25 30100 2.3 3.9 42800 3.3 3.8 25 33900 1.1 31.9 42200 1.9 19.6
30 33900 2.5 4.0 46800 3.6 3.9 30 33800 1.0 32.8 41900 2.0 18.5
40 38000 2.7 4.2 52900 3.8 4.0 40 33100 1.0 32.1 40800 2.1 17.6
50 39000 2.7 4.3 55100 3.9 4.1 50 32400 1.1 28.9 39500 2.7 13.0
60 70 43700 2.9 4.5 61200 4.1 4.3 60 70 31300 1.2 26.3 37500 2.9 11.8
68 49300 3.1 4.7 67000 4.3 4.5 70 30200 1.3 23.0 37200 2.7 12.5
80 57000 3.6 4.7 77500 5.0 4.5 80 29300 1.5 19.7 39900 2.9 12.5
90 59400 3.5 4.9 80800 4.9 4.8 90 32200 2.0 16.0 50000 4.0 11.1
25 28000 2.1 3.8 39800 3.1 3.7 25 43000 0.9 32.6 53500 2.2 24.8
30 31500 2.3 3.9 43500 3.3 3.8 30 42800 0.9 31.3 53000 2.3 23.5
40 35400 2.5 4.1 49200 3.6 4.0 40 42000 1.0 30.1 51600 2.3 22.3
50 36300 2.5 4.2 51200 3.7 4.1 50 41000 1.2 28.9 50000 3.0 16.5
60 80o 40700 2.7 4.4 56900 3.9 4.3 60 80o 39600 1.5 26.3 47500 3.2 15.0
70 45800 2.9 4.6 62300 4.1 4.5 70 38300 1.7 23.0 47000 3.0 15.9
80 53000 3.4 4.6 72100 4.7 4.5 80 37100 1.9 19.7 50500 3.2 15.8
90 55200 3.3 4.9 75100 4.6 4.7 90 40800 2.6 16.0 63200 4.5 14.1
NORTHERN HEAT PUMP
3-201 South Railway Ave

Winkler, Manitoba R6W 1J9, CANADA
Northern Heat Pump Water Source Heat Pumps Phone (204) 325-9772 Fax (204) 325-4954
Water to water heat pumps. XTERRA SERIES
Stainless steel cabinet
Insulated to reduce condensation
Compressor is high efficiency scroll
Safety devices to prevent compressor damage
AQUA2 R410A
RAWE 36
8 gpm loop 5 gpm hyd. 8 gpm loop 5 gpm hyd

HEATING COOLING
LOOP HYD CAP LOOP HYD HR
EWT LWT MBTU/hr KW COP EWT LWT MBTU/hr KW EER
70.0 25.7 1.7 4.4 35.0 31.5 1.6 19.7
85.0 25.6 1.8 4.2 40.0 33.4 1.6 20.8
100.0 25.5 2.1 3.6 50 45.0 35.3 1.6 21.8
25
110.0 25.4 2.3 3.3 50.0 36.6 1.6 22.3
115.0 25.3 2.5 3.0 55.0 37.9 1.7 22.7
120.0 25.2 3.1 2.4 35.0 32.1 1.9 17.1
70.0 28.3 1.6 5.1 40.0 34.1 1.9 18.2
85.0 27.6 1.4 4.7 60 45.0 36.2 1.9 19.3
100.0 27.3 2.0 4.0 50.0 37.7 1.9 19.8
30
110.0 27.1 2.2 3.6 55.0 39.1 1.9 20.3
115.0 27.0 2.4 3.3 35.0 32.8 2.3 14.4
120.0 26.6 3.0 2.6 40.0 34.9 2.2 15.6
70.0 31.0 1.6 5.7 70 45.0 37.1 2.2 16.8
85.0 29.5 1.7 5.2 50.0 38.7 2.2 17.3
100.0 29.1 2.0 4.4 55.0 40.4 2.3 17.8
35
110.0 28.7 2.1 4.0 Data subject to change without notice
115.0 28.7 2.3 3.6
120.0 27.9 2.8 2.9
70.0 32.9 1.5 6.4
85.0 31.4 1.6 5.6
100.0 31.0 1.9 4.7
40
110.0 30.5 2.1 4.3
115.0 30.5 2.3 3.9
120.0 29.7 2.8 3.2
70.0 36.8 1.5 7.0
85.0 37.7 1.8 6.1
100.0 37.1 2.1 5.1
50
110.0 36.5 2.3 4.7
115.0 35.9 2.5 4.2
120.0 34.8 3.0 3.4
R d outside
Rated id the
h scope off ARI
AQUA2 R410A
RAWE 50
11 gpm loop 8 gpm hyd. 11 gpm loop 8 gpm hyd

HEATING COOLING
LOOP HYD CAP LOOP HYD CAP
EWT LWT MBTU/hr KW COP EWT LWT MBTU/hr KW EER
70.0 38.7 2.6 4.4 35.0 39.6 2.1 19.3
85.0 38.8 2.9 3.9 40.0 42.3 2.1 20.4
100.0 38.7 3.4 3.3 50 45.0 44.9 2.1 21.5
25
110.0 38.5 4.0 2.9 50.0 46.8 2.1 21.9
115.0 38.4 4.2 2.7 55.0 48.6 2.2 22.3
120.0 37.9 4.6 2.4 35.0 39.3 2.4 16.7
70.0 40.8 2.3 5.1 40.0 42.3 2.4 17.9
85.0 40.7 2.7 4.4 60 45.0 45.2 2.4 19.0
100.0 40.6 3.2 3.7 50.0 47.2 2.4 19.5
30
110.0 40.4 3.8 3.2 55.0 49.3 2.5 19.9
115.0 40.3 3.9 3.0 35.0 39.1 2.8 14.1
120.0 39.8 4.5 2.6 40.0 42.3 2.8 15.3
70.0 47.0 2.5 5.6 70 45.0 45.4 2.8 16.5
85.0 44.9 2.7 4.9 50.0 47.7 2.8 17.0
100.0 44.3 3.2 4.1 55.0 50.0 2.9 17.5
35
110.0 44.0 3.5 3.7 Data subject to change without notice
115.0 43.7 3.8 3.4
120.0 42.3 4.4 2.9
70.0 50.0 2.4 6.2
85.0 47.7 2.6 5.4
100.0 47.1 3.1 4.5
40
110.0 46.8 3.4 4.1
115.0 46.4 3.7 3.7
120.0 45.0 4.3 3.1
70.0 56.4 2.4 6.8
85.0 57.3 2.8 5.9
100.0 56.4 3.4 4.9
50
110.0 55.5 3.7 4.5
115.0 54.6 4.0 4.0
120.0 53.0 4.7 3.3
Rated outside the scope of ARI

NORTHERN HEAT PUMP INC. Specification Manual Ground Source Heat Pumps XTERRA SERIES FORCAIR RAVE/ RAHE 36 THRU 70 FORCAIR2 RTVE/ RTHE 30 THRU 60 AQUA2 …

Download Now

Documemt Updated

ADVERTISEMENT

Popular Download

ADVERTISEMENT

Frequently Asked Questions

Why choose northern heat pump?

High-tech, efficient, simple, compact, beautifully engineered in a stainless steel shell - are a few of the reasons you should choose Northern Heat Pump for your heating and cooling needs. Click here for more information. Here are two diagrams explaining the process of heating and cooling using Geothermal Heat Pumps

What hvac services are available in upstate ny?

HVAC Services in Upstate NY! Northern Heating and Air in Queensbury NY is ready to take care of all your heating and air conditioning needs, including installation, repair, replacement, and maintenance. Our HVAC services include air conditioners, furnaces, heat pumps, thermostats and boilers for residential and commercial services.

Does northern heating and air offer 24 hour emergency service?

Northern Heating and Air is proud to offer true 24-hour emergency service, so someone is always on call to help, no matter what time of day – or night – you may need us.