1 NEXT-GEN ALL-TEMP Catalog KM-KLX-0817C NEXT-GEN ALL-TEMP LOW PROFILE UNIT COOLER AIR, ELECTRIC & HOT GAS DEFROST MODELS 2,700 to 45,900 BTUH SMALL TO MEDIUM WALK-INS COOLER & FREEZER APPLICATIONS 2 NEXT-GEN ALL-TEMP Features Kramer Low Profile Unit Coolers feature an air draw-through design and are available in air, electric and hot gas defrost configurations. We’ve taken these all-purpose unit coolers to the next level with the release of the Next-Gen All- Temp models. The units feature a new fan guard design and deep draw venturi to achieve optimal airflow, easy access for serviceability, and can be used with multiple refrigerants
SIZES ELECTRICAL There are a wide array of sizes available with capacities Available for 115V, 115-230V (Air Defrost EC motor only), ranging from 2,700 to 45,900 BTUH at a 10° TD. One 208/230V and 460V (see pages 5 through 9). A large through six fan models are available with air flow electrical compartment is supplied internal to the unit to spanning a range of 800 to 4,650 CFM. house the electrical components and is easily accessible by removing the slide out end panel. All models are UL HOUSING and cUL listed and are available for 60 Hz or 50 Hz The embossed aluminum casing is lightweight yet applications
durable. Each fan section is baffled to prevent short cycling of the discharge air. The units are designed to AIR DEFROST mount flush to the ceiling and are compliant with NSF Air Defrost models (KL6A) are designed for use in requirements. The top pan includes 1/2” wide slotted coolers 35°F and warmer. All components are factory mounting points to simplify installation. The removable wired to convenient screw-type terminal strips
drain fitting is installed into the bottom of the drain pan for easy field connection and it can be quickly replaced ELECTRIC DEFROST without changing out the entire drain pan. End panels Electric Defrost models (KL*E) are designed for use can be slid out from the front of the unit providing easy in coolers and freezers between 34°F to -20°F. Defrost serviceability from the front or side of the unit, allowing heaters are mounted on the air intake side of the unit convenient access to the roomy electrical and piping for optimal performance and easy maintenance. A compartments. lower heater is installed inside the drain pan for fast, reliable drainage. A defrost termination fan delay COIL thermostat (DTFD) terminates the defrost cycle when the Copper hairpins consist of high efficiency 3/8” enhanced temperature is satisfied. The fan delay allows the warm copper tubes which are staggered and mechanically coil to cool after a defrost cycle prior to the fans turning expanded into corrugated aluminum fins achieving on. A heater safety thermostat is installed to prevent maximum heat transfer while reducing refrigerant overheating
charge. Die formed fin collars provide even fin spacing
Models are available in 4 and 6 fins per inch. Sweat HOT GAS DEFROST connections are standard on all models. There are two types of Hot Gas Defrost models available: 3-pipe Hot Gas models (KL*H) and 2-pipe Hot Gas MOTORS Reverse Cycle units (KL*G) (see pages 10 through 11 for Standard models feature highly efficient Electronically more details). Hot Gas Defrost models are designed for Commutated (EC) motors that can be field or factory use in coolers and freezers between 34°F and -20°F. All wired for dual speed operation. Dual Speed EC motors Hot Gas units include a fixed DTFD factory wired and an are available for 115V or 208/230V and are compliant electric drain pan heater
with California Title 24 regulations. PSC motors are also available for 115V, 208/230V or 460V requirements. All Optional Features motors include thermal overload protection
• Coated fin pack2 (Baked epoxy, ElectroFin3, Bronz- CONFIGURATIONS Glow, or Heresite) Units are available as fully configurable (no mounted • Coated housing3 (same coatings as above) accessories) or they can be pre-assembled with the most • Adjustable termination/ fan delay control4 requested options pre-installed at the factory. • Insulated drain pan4 Pre-assembly Code1: • Blank = Configurable (no factory installed options) • T = Factory mounted mechanical TXV Notes • L = Factory mounted mechanical TXV, Liquid Line * Asterisk represents a variable character based on fins per Solenoid and mechanical T-Stat inch. See page 4 for nomenclature
• M = Master Configuration with mounted mechanical 1. Codes T, L and M are intended for units in finished goods TXV, mechanical T-Stat, LLS and copper Tee inventory only. Call out each required option separately for units ordered for normal lead time delivery
FANS Heavy duty 12” aluminum fans are balanced to provide 2. Option available for all models
vibration-free operation. New and improved black plastic 3. ElectroFin coating is not NSF approved. NSF approval label fan guard design and deep draw venturi provide an will be removed from unit if ordered with this coating
optimal air pattern. 4. Option available for electric and hot gas defrost models
3 Low Profile Unit CoolerHighlighted Features and OptionsFANS HOUSING• 12” heavy duty aluminum fans are balanced for • Lightweight and durable embossed aluminum vibration-free operation casing• High efficiency fan guard design and deep • Mounts flush to ceiling to maximize storage draw venturi provide optimal air flow space • Slide out end panels • NSF approved ELECTRICAL AND PIPING Unit shown with optional components installed • End panels slide out for easy service from the front or sides of the unit • Ample room in electrical and piping compartments for easy access COILS AND DEFROST HEATERS • Available in 4 or 6 fins per inch (FPI) • Electric defrost heaters are mounted on the air intake coil face to provide optimal performance and easy service access • The drain pan heater is affixed to the drain pan and is easily removable for service or cleaning 4 NEXT-GEN ALL-TEMP Electronically commutated motors bring energy efficiency to the refrigeration Unit Cooler market. Features of the EC motors we offer include: • Integrated control with sealed construction • Locked rotor and overload protection • Durable ball bearing construction for long commercial life • Unique Hall Effect Sensor design prevents syncing or resonance • Threaded shaft uses hubless fan blade • Motors can be configured for single or dual speed operation • Dual voltage motor internal power supply operates at correct rpm from 115-230 VAC Energy Savings by Switching from PSC to Efficient EC Motor Chart is based on Energy Cost of $0.10 per kWh
Change Reduced Run Motor Motor Yearly Std Motor Reduced Unit Pay Motor to Motor Power Time Energy Energy Saving Power Box Load Energy back Change Power Watts/ Hrs/ Savings Savings $ Per Watts/Mtr MBTU/Yr Savings in Yrs Watts/Mtr Mtr Day kWh/Yr $/Yr MTR $/Yr PSC to 85 47 38 22 305 31 1041 20 51 2.0 EC PSC = 1/20 HP PSC motor EC = 50 Watt Electronically Commutated motor Yearly Savings by Switching from PSC to EC Motor $120 $100 Dollars Saved $80 $60 PSC to EC $40 $20 $0 1 2 3 4 5 6 7 8 9 10 11 12 Months of Year MODEL NUMBER NOMENCLATURE K L 6 E 042 D E A B L Pre-assembly Code Kramer Blank = Configurable (No factory Model Type* installed options) L = Low Profile - Std. Connections T = Mounted TXV only U = Low Profile - Opposite End Conn. L = Mounted TXV, LLS, T-Stat M = Master Configuration with Fins Per Inch TXV, LLS, T-Stat, Copper Tube 4 FPI 6 FPI See features page for configuration descriptions Type of Defrost A = Air Defrost Refrigerant Type E = Electric Defrost A = R404A G = Glycol* H = Hot Gas 3 Pipe B = R407A (Consult Factory) G = Hot Gas Rev. Cycle 2 Pipe C = R407C S = R407A, R448A, BTUH in Hundreds D = R407F R449A/B E = R448A, Revision Code * More information Voltage Code R449A/B can be found in the A = 115/1/60 L = 100/1/50 S = 115-230/1/50-60 Motor Type F = CO2 DX Glycol Unit Coolers D = 208-230/1/60 M = 200-220/1/50 (Air Defrost EC E = Single Speed ECM publication, KM-GLX, E = 208-230/3/60 N = 200-220/3/50 motor only) D = Dual Speed ECM on our Website
F = 460/1/60 P = 380/1/50 P = PSC * NOTE: Refrigerant and electrical connection locations have been changed for the Next-Gen All-Temp design. Standard connections (“L”) are now opposite of the legacy All-Temp models. Mirror image connections (“U” - same end as legacy LP models) are available only as built-to-order base units with no installed options. Refer to the drawing on the back cover for more detail
5 Low Profile Unit CoolerPerformance and Electrical Data - Air Defrost Models - 6 FPI BTUH Capacity Total Fan Motor AMPS - 1 Phase @ 25°F S.T. & MCA MOPD 10°F TD No. EC Motors† PSC Motors Model CFM of Number R407A/ 115V/ 115V/ R404A/ Fans 208- 208- R448A/ 115V 115V 460V 208-230V/ 208-230V/ CO2 DX 230V 230V R449A/B^ 460V 460V KL6A041*** 4,100 4,800 800 1 0.8 0.5 1.0 0.5 0.4 KL6A052*** 5,200 6,000 785 1 0.8 0.5 1.0 0.5 0.4 15.0 20 KL6A066*** 6,600 7,800 775 1 0.8 0.5 1.0 0.5 0.4 KL6A073*** 7,300 8,500 1,600 2 1.6 1.0 2.0 1.0 0.8 KL6A094*** 9,400 10,900 1,570 2 1.6 1.0 2.0 1.0 0.8 15.0 20 KL6A117*** 11,700 13,600 1,550 2 1.6 1.0 2.0 1.0 0.8 KL6A130*** 13,000 15,300 1,550 2 1.6 1.0 2.0 1.0 0.8 KL6A141*** 14,100 16,300 2,355 3 2.4 1.5 3.0 1.5 1.2 15.0 20 KL6A161*** 16,100 18,800 2,355 3 2.4 1.5 3.0 1.5 1.2 KL6A181*** 18,100 21,200 2,325 3 2.4 1.5 3.0 1.5 1.2 KL6A195*** 19,500 22,500 3,140 4 3.2 2.0 4.0 2.0 1.6 15.0 20 KL6A235*** 23,500 27,800 3,140 4 3.2 2.0 4.0 2.0 1.6 KL6A260*** 26,000 30,400 3,100 4 3.2 2.0 4.0 2.0 1.6 KL6A295*** 29,500 36,100 3,875 5 4.0 2.5 5.0 2.5 2.0 15.0 20 KL6A330*** 33,000 38,800 4,650 6 4.8 3.0 6.0 3.0 2.4 KL6A390*** 39,000 45,900 4,650 6 4.8 3.0 6.0 3.0 2.4Use EC motors for 50 Hz operation
* Each asterisk represents a variable character based on voltage, motor and vintage ordered. See page 4 for nomenclature
^ Refrigerants with large glides are rated at dew point temperature. Use R407A capacity ratings for R407C and R407F
† These Electronically Commutated (EC) Motors are not available for 460V. EC Motors can be field or factory wired for dual-speed operation. Dual-speed EC motors are compliant with California Title 24 regulations
Energy Independence and Security Act of 2007 specifies that walk-in coolers and freezers under 3,000 square feet thatare manufactured after January 1, 2009 shall have evaporators with EC motors when they are single phase, less than460 volt and less than 1 HP
Mounts flush to the ceiling to maximize storage space UL certified for use with multiple refrigerants Single fan through six fan models are available 6 NEXT-GEN ALL-TEMP Performance and Electrical Data - Electric Defrost Models - 6 FPI BTUH Capacity Total Fan Motor AMPS - 1 Phase @ -20°F S.T. & MCA MOPD 10°F TD1 No. EC Motors† PSC Motors Model CFM of Number R407A/ R404A / Fans 230V/ 230V/ R448A/ 230V 230V 460V CO2 DX 460V 460V R449A/B^ KL6E035*** 3,500 4,000 800 1 0.5 0.5 0.4 KL6E042*** 4,200 4,900 785 1 0.5 0.5 0.4 15.0 20 KL6E049*** 4,900 5,600 775 1 0.5 0.5 0.4 KL6E066*** 6,600 7,600 1,600 2 1.0 1.0 0.8 KL6E077*** 7,700 8,800 1,570 2 1.0 1.0 0.8 15.0 20 KL6E090*** 9,000 10,600 1,550 2 1.0 1.0 0.8 KL6E105*** 10,500 12,400 1,550 2 1.0 1.0 0.8 KL6E121*** 12,100 14,200 2,355 3 1.5 1.5 1.2 15.0 20 KL6E142*** 14,200 16,600 2,325 3 1.5 1.5 1.2 KL6E162*** 16,200 18,700 3,140 4 2.0 2.0 1.6 KL6E182*** 18,200 21,000 3,100 4 2.0 2.0 1.6 15.0 20 KL6E200*** 20,000 22,800 3,925 5 2.5 2.5 2.0 KL6E244*** 24,400 27,900 4,710 6 3.0 3.0 2.4 15.0 20 KL6E281*** 28,100 33,000 4,650 6 3.0 3.0 2.4 Heater Amps 1 Capacity Correction for Electric and 230V 460V Hot Gas Defrost Evaporators Model Heater S.S.T. (dew) 20ºF 0ºF -10ºF -20ºF -30ºF Number Watts 1PH 3PH 1PH Multiply 1.15 1.075 1.0375 1 0.9625 Capacity by: KL6E035*** 4.9 – 2.5 1,125 KL6E042*** 4.9 – 2.5 1,125 KL6E049*** 4.9 – 2.5 1,125 KL6E066*** 9.8 – 4.9 2,250 KL6E077*** 9.8 – 4.9 2,250 KL6E090*** 9.8 – 4.9 2,250 KL6E105*** 9.8 – 4.9 2,250 KL6E121*** 14.3 – 7.2 3,300 KL6E142*** 14.3 – 7.2 3,300 KL6E162*** 19.2 – 9.6 4,425 KL6E182*** 19.2 – 9.6 4,425 KL6E200*** 24.1 14.0 12.0 5,550 KL6E244*** 29.0 16.8 14.5 6,675 KL6E281*** 29.0 16.8 14.5 6,675 Use EC motors for 50 Hz operation
– Not available
* Each asterisk represents a variable character based on voltage, motor and vintage ordered. See page 4 for nomenclature
^ Refrigerants with large glides are rated at dew point temperature. Use R407A capacity ratings for R407C and R407F
† These Electronically Commutated (EC) Motors are not available for 460V. EC Motors can be field or factory wired for dual-speed operation. Dual-speed EC motors are compliant with California Title 24 regulations
Energy Independence and Security Act of 2007 specifies that walk-in coolers and freezers under 3,000 square feet that are manufactured after January 1, 2009 shall have evaporators with EC motors when they are single phase, less than 460 volt and less than 1 HP
7 Low Profile Unit CoolerPerformance and Electrical Data - Electric Defrost - 4 FPI BTUH Capacity Total Fan Motor AMPS - 1 Phase @ -20°F S.T. & MCA MOPD 10°F TD1 No. EC Motors† PSC Motors Model CFM of Number R407A/ R404A / Fans 230V/ 230V/ R448A/ 230V 230V 460V CO2 DX 460V 460V R449A/B^ KL4E027*** 2,700 3,100 800 1 0.5 0.5 0.4 KL4E032*** 3,200 3,800 785 1 0.5 0.5 0.4 15.0 20 KL4E038*** 3,800 4,400 775 1 0.5 0.5 0.4 KL4E051*** 5,100 5,900 1,600 2 1.0 1.0 0.8 KL4E064*** 6,400 7,300 1,570 2 1.0 1.0 0.8 15.0 20 KL4E080*** 8,000 9,500 1,550 2 1.0 1.0 0.8 KL4E094*** 9,400 11,000 2,355 3 1.5 1.5 1.2 KL4E110*** 11,000 12,800 2,325 3 1.5 1.5 1.2 15.0 20 KL4E125*** 12,500 14,400 3,140 4 2.0 2.0 1.6 KL4E141*** 14,100 16,300 3,100 4 2.0 2.0 1.6 KL4E155*** 15,500 17,700 3,925 5 2.5 2.5 2.0 15.0 20 KL4E195*** 19,500 22,300 4,710 6 3.0 3.0 2.4 KL4E230*** 23,000 27,000 4,650 6 3.0 3.0 2.4 Heater Amps 1 Capacity Correction for Electric and 230V 460V Hot Gas Defrost Evaporators Model Heater S.S.T. (dew) 20ºF 0ºF -10ºF -20ºF -30ºF Number Watts 1PH 3PH 1PH Multiply 1.15 1.075 1.0375 1 0.9625 Capacity by: KL4E027*** 4.9 – 2.5 1,125 KL4E032*** 4.9 – 2.5 1,125 KL4E038*** 4.9 – 2.5 1,125 KL4E051*** 9.8 – 4.9 2,250 KL4E064*** 9.8 – 4.9 2,250 KL4E080*** 9.8 – 4.9 2,250 KL4E094*** 14.3 – 7.2 3,300 KL4E110*** 14.3 – 7.2 3,300 KL4E125*** 19.2 – 9.6 4,425 KL4E141*** 19.2 – 9.6 4,425 KL4E155*** 24.1 14.0 12.0 5,550 KL4E195*** 29.0 16.8 14.5 6,675 KL4E230*** 29.0 16.8 14.5 6,675Use EC motors for 50 Hz operation
– Not available
* Each asterisk represents a variable character based on voltage, motor and vintage ordered. See page 4 for nomenclature
^ Refrigerants with large glides are rated at dew point temperature. Use R407A capacity ratings for R407C and R407F
† These Electronically Commutated (EC) Motors are not available for 460V. EC Motors can be field or factory wired for dual-speed operation. Dual-speed EC motors are compliant with California Title 24 regulations
Energy Independence and Security Act of 2007 specifies that walk-in coolers and freezers under 3,000 square feet thatare manufactured after January 1, 2009 shall have evaporators with EC motors when they are single phase, less than460 volt and less than 1 HP
8 NEXT-GEN ALL-TEMP Electric Defrost Kits MODEL 1 UNIT COOLER PER SYSTEM 2 UNIT COOLERS PER SYSTEM 3 UNIT COOLERS PER SYSTEM NUMBER 230V/1 230V/3 460V/1 230V/1 230V/3 460V/1 230V/1 230V/3 460V/1 6 FPI KL6E035*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL6E042*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL6E049*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL6E066*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL6E077*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL6E090*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL6E105*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED33-A2 – ED32-A4 KL6E121*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED33-A2 – ED32-A4 KL6E142*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED33-A2 – ED32-A4 KL6E162*** ED6-A2 – ED17-A4 ED23-A2* – ED22-A4 ED35-A2 – ED32-A4 KL6E182*** ED6-A2 – ED17-A4 ED23-A2* – ED22-A4 ED35-A2 – ED32-A4 KL6E200*** ED7-A2 ED11-B2 ED17-A4 ED23-A2* ED21-B2* ED22-A4 ED35-A2 ED33-B2 ED34-A4 KL6E244*** ED7-A2 ED11-B2 ED17-A4 ED25-A2* ED23-B2* ED22-A4 ED35-A2 ED35-B2 ED34-A4 KL6E281*** ED7-A2 ED11-B2 ED17-A4 ED25-A2* ED23-B2* ED22-A4 ED35-A2 ED35-B2 ED34-A4 4 FPI KL4E027*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E032*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E038*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E051*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E064*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E080*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E094*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED30-A2 – ED32-A4 KL4E110*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED33-A2 – ED32-A4 KL4E125*** ED5-A2 – ED17-A4 ED20-A2* – ED22-A4 ED33-A2 – ED32-A4 KL4E141*** ED6-A2 – ED17-A4 ED23-A2* – ED22-A4 ED35-A2 – ED32-A4 KL4E155*** ED6-A2 ED11-B2 ED17-A4 ED23-A2* ED21-B2* ED22-A4 ED35-A2 ED33-B2 ED32-A4 KL4E195*** ED7-A2 ED11-B2 ED17-A4 ED23-A2* ED23-B2* ED22-A4 ED35-A2 ED35-B2 ED34-A4 KL4E230*** ED7-A2 ED11-B2 ED17-A4 ED23-A2* ED23-B2* ED22-A4 ED35-A2 ED35-B2 ED34-A4 * 1/2 through 3 HP condensing units require ED210 or ED213 for systems with 2 evaporators. ED213 is not large enough for use with six-fan evaporators
– Not available
See additional notes on page 9
ELECTRIC DEFROST KIT NOMENCLATURE ED 12 - A2 Defrost Heater Voltage (2 = 208-230V, 4 = 460V) Defrost Heater Phase (1 or 3) A = 1 Phase Fan Motors, 1 Phase Heaters B = 1 Phase Fan Motors, 3 Phase Heaters C = 3 Phase Fan Motors, 3 Phase Heaters Defrost Kit Identifier Evaporator Quantity (1, 2, or 3 per system) Kit Designator 9 Low Profile Unit CoolerElectric Defrost Kits KIT AUXILIARY BLOCK-OUT DEFROST FAN SEQUENCING TIMER NUMBER SWITCH RELAY CONTACTOR CONTACTOR RELAY ED5-230/1 1 – 1-15A – – – ED6-230/1 1 – 1-20A – – – ED7-230/1 1 – 1-25A – – – ED10-230/1 1 – 1-30A – – – ED11-230/3 1 1 – 1-30A – – ED17-460/1 1 1 – 1-15A 1-15A – ED18-460/1 1 1 – 1-20A 1-20A – ED12-460/1 1 1 – 1-30A 1-25A – 1 ED210-230/1 1 – 1-30A – – – 1 ED213-230/1 1 1 — 1-50A – – 1 ED213-230/3 1 1 — 1-50A – – ED20-230/1 1 – 1-30A – – 2 ED22-460/1 1 1 — 2-15A 1-25A 2 ED23-230/1 1 1 — 2-25A – 2 ED23-230/3 1 1 — 2-25A – 2 ED30-230/1 1 – 1-30A – – 3 ED32-460/1 1 1 – 3-10A 1-25A 3 ED33-230/1 1 1 – 3-16A — 3 ED34-460/1 1 1 – 3-16A 1-25A 3 ED35-230/1 1 1 – 3-33A – 3 ED35-230/3 1 1 – 3-33A – 3Electric defrost kits consist of components that are necessary to control the defrost cycle. The kits are available asa factory installed option when ordered with a condensing unit. Not all Ed-Kits are available for all condensing unitmodels. The contents of each kit is described below, along with the function of each component
Timer: Initiates the defrost cycle. Also used as a override protection for defrost termination
Auxiliary Switch: It’s mounted on the compressor contactor and prevents the defrost contactor from operating whenever the compressor is energized
Block-Out Relay: Serves the same function as auxiliary switch. Used when defrost contactor is not required (lower wattage single phase only)
Defrost Contactor: Carries amperage load for heaters
Fan Contactor: Used with 460V motors or when 230V motors are wired 3 phase
Sequencing Relays: Provides interconnection of multiple unit coolers on a single system so that each unit cooler is allowed to individually terminate defrost on temperature
– Not available
¹ For use with 2 evaporators , 1/2 through 3 HP Next-Gen K-Series systems ONLY! ED213 is not large enough for six-fan evaporators
Defrost Kit Components DEFROST CONTACTOR FAN AUXILIARY CONTACTOR SWITCH SEQUENCING BLOCK-OUT RELAY RELAY TIMER 10 NEXT-GEN ALL-TEMP Performance and Electrical Data - Hot Gas Defrost - 6 FPI BTUH Capacity Total Fan Motor AMPS - 1 Phase Hot Gas @ -20°F S.T. & MCA MOPD Hot Gas Reverse EC Motors† PSC Motors 10°F TD1 No
3-Pipe Cycle CFM of 115V/ 115V/ Model 2-Pipe R407A/ R404A/ Fans 208- 208- 208- 208- Number Model R448A/ 115V 115V 460V Number CO2 DX 230V 230V 230V/ 230V/ R449A/B^ 460V 460V KL6H035*** KL6G035*** 3,500 4,000 800 1 0.8 0.5 0.8 0.5 0.4 KL6H042*** KL6G042*** 4,200 4,900 785 1 0.8 0.5 0.8 0.5 0.4 15.0 20 KL6H049*** KL6G049*** 4,900 5,600 775 1 0.8 0.5 0.8 0.5 0.4 KL6H066*** KL6G066*** 6,600 7,600 1,600 2 1.6 1.0 1.6 1.0 0.8 KL6H077*** KL6G077*** 7,700 8,800 1,570 2 1.6 1.0 1.6 1.0 0.8 15.0 20 KL6H090*** KL6G090*** 9,000 10,600 1,550 2 1.6 1.0 1.6 1.0 0.8 KL6H105*** KL6G105*** 10,500 12,400 1,550 2 1.6 1.0 1.6 1.0 0.8 KL6H121*** KL6G121*** 12,100 14,200 2,355 3 2.4 1.5 2.4 1.5 1.2 15.0 20 KL6H142*** KL6G142*** 14,200 16,600 2,325 3 2.4 1.5 2.4 1.5 1.2 KL6H162*** KL6G162*** 16,200 18,700 3,140 4 3.2 2.0 3.2 2.0 1.6 KL6H182*** KL6G182*** 18,200 21,000 3,100 4 3.2 2.0 3.2 2.0 1.6 15.0 20 KL6H200*** KL6G200*** 20,000 22,800 3,925 5 4.0 2.5 4.0 2.5 2.0 KL6H244*** KL6G244*** 24,400 27,900 4,710 6 4.8 3.0 4.8 3.0 2.4 15.0 20 KL6H281*** KL6G281*** 28,100 33,000 4,650 6 4.8 3.0 4.8 3.0 2.4 Hot Gas Drain Pan Hot Gas Reverse Drain Hot Gas 3-Pipe Model Heater Amps 3-Pipe Cycle Pan The system uses 3 pipes — 1 for liquid line, 1 for suction line and 1 for hot gas. The hot gas is taken Model 2-Pipe 115V 230V 460V Heater from the discharge line, between the compressor Number Model Watts and the condenser, through a hot-gas solenoid Number 1PH 1PH 1PH valve to the distributor tee then through the coil
KL6H035*** KL6G035*** 3.1 1.7 0.9 375 KL6H042*** KL6G042*** 3.1 1.7 0.9 375 KL6H049*** KL6G049*** 3.1 1.7 0.9 375 KL6H066*** KL6G066*** 6.3 3.3 1.7 750 KL6H077*** KL6G077*** 6.3 3.3 1.7 750 KL6H090*** KL6G090*** 6.3 3.3 1.7 750 KL6H105*** KL6G105*** 6.3 3.3 1.7 750 KL6H121*** KL6G121*** 9.3 4.8 2.4 1,100 KL6H142*** KL6G142*** 9.3 4.8 2.4 1,100 KL6H162*** KL6G162*** 12.3 6.4 3.2 1,475 KL6H182*** KL6G182*** 12.3 6.4 3.2 1,475 KL6H200*** KL6G200*** 15.4 8.1 4.0 1,850 KL6H244*** KL6G244*** 18.5 9.7 4.9 2,225 KL6H281*** KL6G281*** 18.5 9.7 4.9 2,225 1 Capacity Correction for Electric and Hot Gas Defrost Evaporators S.S.T. (Dew) 20ºF 0ºF -10ºF -20ºF -30ºF Multiply Capacity by: 1.15 1.075 1.0375 1 0.9625 Use EC motors for 50 Hz operation
* Each asterisk represents a variable character based on voltage, motor and vintage ordered. See page 4 for nomenclature
^ Refrigerants with large glides are rated at dew point temperature. Use R407A capacity ratings for R407C and R407F
† These Electronically Commutated (EC) Motors are not available for 460V. EC Motors can be field or factory wired for dual- speed operation. Dual-speed EC motors are compliant with California Title 24 regulations
Energy Independence and Security Act of 2007 specifies that walk-in coolers and freezers under 3,000 square feet that are manufactured after January 1, 2009 shall have evaporators with EC motors when they are single phase, less than 460 volt and less than 1 HP
11 Low Profile Unit CoolerPerformance and Electrical Data - Hot Gas Defrost - 4 FPI BTUH Capacity Total Fan Motor AMPS - 1 Phase Hot Gas @ -20°F S.T. & 10°F MCA MOPD Hot Gas Reverse EC Motors† PSC Motors TD1 No
3-Pipe Cycle CFM of 115V/ 115V/ Model 2-Pipe R407A/ R404A/ Fans 208- 208- 208- 208- Number Model R448A/ 115V 115V 460V Number CO2 DX 230V 230V 230V/ 230V/ R449A/B^ 460V 460V KL4H027*** KL4G027*** 2,700 3,100 800 1 0.8 0.5 0.8 0.5 0.4 KL4H032*** KL4G032*** 3,200 3,800 785 1 0.8 0.5 0.8 0.5 0.4 15.0 20.0 KL4H038*** KL4G038*** 3,800 4,400 775 1 0.8 0.5 0.8 0.5 0.4 KL4H051*** KL4G051*** 5,100 5,900 1,600 2 1.6 1.0 1.6 1.0 0.8 KL4H064*** KL4G064*** 6,400 7,300 1,570 2 1.6 1.0 1.6 1.0 0.8 15.0 20.0 KL4H080*** KL4G080*** 8,000 9,500 1,550 2 1.6 1.0 1.6 1.0 0.8 KL4H094*** KL4G094*** 9,400 11,000 2,355 3 2.4 1.5 2.4 1.5 1.2 KL4H110*** KL4G110*** 11,000 12,800 2,325 3 2.4 1.5 2.4 1.5 1.2 15.0 20.0 KL4H125*** KL4G125*** 12,500 14,400 3,140 4 3.2 2.0 3.2 2.0 1.6 KL4H141*** KL4G141*** 14,100 16,300 3,100 4 3.2 2.0 3.2 2.0 1.6 KL4H155*** KL4G155*** 15,500 17,700 3,925 5 4.0 2.5 4.0 2.5 2.0 15.0 20.0 KL4H195*** KL4G195*** 19,500 22,300 4,710 6 4.8 3.0 4.8 3.0 2.4 KL4H230*** KL4G230*** 23,000 27,000 4,650 6 4.8 3.0 4.8 3.0 2.4 Hot Gas Drain Pan Heater Hot Gas Reverse Cycle 2-Pipe Model Hot Gas Reverse Amps Drain A changeover valve is located in the discharge 3-Pipe Cycle Pan suction line of the compressor, so that when defrost Model 2-Pipe 115V 230V 460V Heater is required, the valve changes over from the normal Number Model Watts refrigeration flow so that the discharged gas flows 1PH 1PH 1PH into the suction connection and bypasses TX valve
Number KL4H027*** KL4G027*** 3.1 1.7 0.9 375 KL4H032*** KL4G032*** 3.1 1.7 0.9 375 KL4H038*** KL4G038*** 3.1 1.7 0.9 375 KL4H051*** KL4G051*** 6.3 3.3 1.7 750 KL4H064*** KL4G064*** 6.3 3.3 1.7 750 KL4H080*** KL4G080*** 6.3 3.3 1.7 750 KL4H094*** KL4G094*** 9.3 4.8 2.4 1,100 KL4H110*** KL4G110*** 9.3 4.8 2.4 1,100 KL4H125*** KL4G125*** 12.3 6.4 3.2 1,475 KL4H141*** KL4G141*** 12.3 6.4 3.2 1,475 KL4H155*** KL4G155*** 15.4 8.1 4.0 1,850 KL4H195*** KL4G195*** 18.5 9.7 4.9 2,225 KL4H230*** KL4G230*** 18.5 9.7 4.9 2,225 1 Capacity Correction for Electric and Hot Gas Defrost Evaporators S.S.T. (Dew) 20ºF 0ºF -10ºF -20ºF -30ºF Multiply Capacity by: 1.15 1.075 1.0375 1 0.9625Use EC motors for 50 Hz operation
* Each asterisk represents a variable character based on voltage, motor and vintage ordered. See page 4 for nomenclature
^ Refrigerants with large glides are rated at dew point temperature. Use R407A capacity ratings for R407C and R407F
† These Electronically Commutated (EC) Motors are not available for 460V. EC Motors can be field or factory wired for dual-speed operation. Dual-speed EC motors are compliant with California Title 24 regulations
Energy Independence and Security Act of 2007 specifies that walk-in coolers and freezers under 3,000 square feet that aremanufactured after January 1, 2009 shall have evaporators with EC motors when they are single phase, less than 460 voltand less than 1 HP
12 NEXT-GEN ALL-TEMP Distributor Nozzle and Expansion Valves - Air Defrost Models Part Numbers No
Model Nozzle @ Liq. Temp. TXV^ @ Liq. Temp. EEV @ Liq. Temp. of Number 50°F 100°F 50°F 100°F 50°F 100°F Circuits R404A KL6A041*** – – SBFSE-AAA-C SBFSE-AAA-C SER-AA SER-AA 1 KL6A052*** – – SBFSE-AAA-C SBFSE-AAA-C SER-AA SER-AA 1 KL6A066*** L, #1/9 L, #1/3 SBFSE-AAA-C SBFSE-AA-C SER-AA SER-AA 2 KL6A073*** L, #1/6 L, #1/3 SBFSE-AAA-C SBFSE-AA-C SER-AA SER-AA 2 KL6A094*** L, #1/6 L, #1/2 SBFSE-AA-C SBFSE-A-C SER-AA SER-A 2 KL6A117*** L, #1/4 L, #3/4 SBFSE-AA-C SBFSE-A-C SER-A SER-A 3 KL6A130*** L, #1/4 L, #3/4 SBFSE-AA-C SBFSE-A-C SER-A SER-A 3 6 KL6A141*** L, #1/4 L, #3/4 SBFSE-A-C SBFSE-A-C SER-A SER-A 4 FPI KL6A161*** L, #1/4 L, #3/4 SBFSE-A-C SBFSE-A-C SER-A SER-A 3 KL6A181*** L, #1/3 L, #1 SBFSE-A-C SBFSE-A-C SER-A SER-B 4 KL6A195*** L, #1/3 L, #1 SBFSE-A-C SBFSE-A-C SER-A SER-B 4 KL6A235*** L, #1/3 L, #1 SBFSE-A-C SBFSE-B-C SER-A SER-B 6 KL6A260*** L, #1/2 L, #1-1/2 SBFSE-A-C SBFSE-B-C SER-B SER-B 6 KL6A295*** L, #1/2 L, #1-1/2 SBFSE-B-C SBFSE-B-C SER-B SER-B 8 KL6A330*** L, #3/4 L, #2 SBFSE-B-C SBFSE-B-C SER-B SER-C 7 KL6A390*** L, #3/4 L, #2 SBFSE-B-C SBFSE-B-C SER-B SER-C 8 R407A/ R448A/ R449A/B† KL6A041*** – – SBFDE-AAA-C SBFDE-AAA-C SER-AA SER-AA 1 KL6A052*** – – SBFDE-AAA-C SBFDE-AAA-C SER-AA SER-AA 1 KL6A066*** L, #1/6 L, #1/3 SBFDE-AAA-C SBFDE-AA-C SER-AA SER-AA 2 KL6A073*** L, #1/6 L, #1/3 SBFDE-AA-C SBFDE-AA-C SER-AA SER-AA 2 KL6A094*** L, #1/4 L, #1/2 SBFDE-AA-C SBFDE-AA-C SER-AA SER-A 2 KL6A117*** L, #1/4 L, #3/4 SBFDE-AA-C SBFDE-A-C SER-A SER-A 3 KL6A130*** L, #1/4 L, #3/4 SBFDE-AA-C SBFDE-A-C SER-A SER-A 3 6 KL6A141*** L, #1/3 L, #3/4 SBFDE-AA-C SBFDE-A-C SER-A SER-A 4 FPI KL6A161*** L, #1/3 L, #3/4 SBFDE-AA-C SBFDE-A-C SER-A SER-A 3 KL6A181*** L, #1/2 L, #1 SBFDE-A-C SBFDE-A-C SER-A SER-B 4 KL6A195*** L, #1/2 L, #1 SBFDE-A-C SBFDE-A-C SER-A SER-B 4 KL6A235*** L, #1/2 L, #1-1/2 SBFDE-A-C SBFDE-A-C SER-A SER-B 6 KL6A260*** L, #3/4 L, #1-1/2 SBFDE-A-C SBFDE-B-C SER-B SER-B 6 KL6A295*** L, #3/4 L, #2 SBFDE-B-C SBFDE-B-C SER-B SER-C 8 KL6A330*** L, #3/4 L, #2 SBFDE-B-C SBFDE-B-C SER-B SER-C 7 KL6A390*** L, #1 L, #2 SBFDE-B-C SBFDE-B-C SER-B SER-C 8 Distributor lines are 3/16” diameter and 14” long. Distributor connection size is 1/2” for all air defrost models
* Each asterisk represents a variable character based on voltage, motor and vintage ordered. See page 4 for nomenclature
– Single feed circuit coils do not get a distributor/nozzle
^ TXV selections are based on +25°F suction temp., 8°F to 12°F evaporator TD. Contact factory for operating conditions outside of this range
† SBFDE expansion valves are compatible with R407A, R448A and R449A/B. For other valves, follow manufacturers selection guidelines
Base models (no factory-mounted components) include nozzles sized for 100°F liquid shipped loose
L = Low Profile - Std. Connections U = Low Profile - Opposite End Conn. Refrigerant Type A = R404A B = R407A C = R407C D = R407F E = R448A, R449A/B F = CO 2 DX G = Glycol* …
Heatcraft Low Profile Unit Coolers have been engineered for efficiency and improved air circulation. Features such as hinged and removable access panels, a hinged drain pan and an easy service motor mount reduce maintenance time and cost. Hinged, removable panels allows for easy access to components.
Cryorig C7 is another low-profile cooler that should fit in any ultra slim computer chassis. It is taller than the SilverStone alternative at a height of 47 mm, but still quite short considering Intel’s stock cooler is around 60 mm. With a price tag of $30 and a six-year warranty, the Cryorig C7 is another great value low-profile cooler.
This low-profile cooler is just 34 mm tall, making it one of the thinnest air coolers available. Naturally, with such a tiny heatsink, it won’t be able to deliver impressive thermal performance. In fact, if possible, we recommend going with a slightly bigger cooler.
Those coolers tend to feature comparatively massive heatsinks, coupled with larger radiators and fans amongst other vital components for optimal airflow and enhanced heat dissipation to give you slight-to-extreme overclocking headspace.